AT commands
Parameter
0x01
0x02
Parameter
0
1
2
Default
0x00

SB (Stop Bits)

This command applies to the XBee SX 868 RF Module.
Sets or displays the number of stop bits for UART communications.
Parameter range
0 - 1
Parameter
0
1
Default
0
RO (Packetization Timeout)
This command applies to the XBee SX 868 RF Module.
Set or read the number of character times of inter-character silence required before transmission
begins when operating in Transparent mode.
Set RO to 0 to transmit characters as they arrive instead of buffering them into one RF packet.
Parameter range
0 - 0xFF (x character times)
Default
3

FT (Flow Control Threshold)

This command applies to the XBee SX 868 RF Module.
Set or display the flow control threshold.
XBee® SX 868 RF Module User Guide
Description
Even parity
Odd parity
Description
No parity
Even parity
Odd parity
Configuration
One stop bit
Two stop bits
Serial interfacing commands
131