Ni (Node Identifier); Nt (Network Discovery Back-Off); No (Network Discovery Options) - Digi XBee SX User Manual

Radio frequency (rf) module
Hide thumbs Also See for XBee SX:
Table of Contents

Advertisement

AT commands
When you set BR to 0 the TO option has the DigiMesh and Repeater mode disabled automatically.
Default
0xC0

NI (Node Identifier)

Stores the node identifier string for a device, which is a user-defined name or description of the
device. This can be up to 20 ASCII characters.
XCTU prevents you from exceeding the string limit of 20 characters for this command. If you
n
are using another software application to send the string, you can enter longer strings, but the
software on the device returns an error.
Parameter range
A string of case-sensitive ASCII printable characters from 0 to 20 bytes in length. The string cannot
start with the space character. A carriage return or a comma automatically ends the command.
Default
0x20 (an ASCII space character)

NT (Network Discovery Back-off)

Sets or displays the network discovery back-off parameter for a device. This sets the maximum value
for the random delay that the device uses to send network discovery responses.
Parameter range
0x20 - 0x2EE0 (x 100 ms)
Default
0x82 (13 seconds)

NO (Network Discovery Options)

Set or read the network discovery options value for the ND (Network Discovery) command on a
particular device. The options bit field value changes the behavior of the ND command and what
optional values the local device returns when it receives an ND command or API Node Identification
Indicator (0x95) frame.
Use NO to suppress or include a self-response to ND (Node Discover) commands. When NO bit 1 = 1, a
device performing a Node Discover includes a response entry for itself.
Parameter range
0x0 - 0x7 (bit field)
XBee®/XBee-PRO SX RF Module User Guide
Addressing commands
76

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xbee-pro sx

Table of Contents