AT commands
XCTU prevents you from exceeding the string limit of 20 characters for this command. If you
n
are using another software application to send the string, you can enter longer strings, but the
software on the device returns an error.
Use the ND (Network Discovery) command with this string as an argument to easily identify devices
on the network.
The DN command also uses this identifier.
Parameter range
A string of case-sensitive ASCII printable characters from 0 to 20 bytes in length. A carriage return
or a comma automatically ends the command.
Default
0x20 (an ASCII space character)

NT (Network Discovery Back-off)

Sets or displays the network discovery back-off parameter for a device. This sets the maximum value
for the random delay that the device uses to send network discovery responses.
The ND and FN commands use NT. The read-only N? command increases and decreases with NT.
Parameter range
0x20 - 0x2EE0 (x 100 ms)
Default
0x82 (13 seconds)

N? (Network Discovery Timeout)

The maximum response time, in milliseconds, for ND (Network Discovery) responses and DN (Discover
Node) responses. The timeout is the sum of NT (Network Discovery Back-off Time) and the network
propagation time.
Parameter range
This is a read-only parameter, however, its value increases or decreases as NT increases or
decreases and you can modify NT.
Default
N/A

NO (Network Discovery Options)

Set or read the network discovery options value for the ND (Network Discovery) command on a
particular device. The options bit field value changes the behavior of the ND command and what
optional values the local device returns when it receives an ND command or API Node Identification
Indicator (0x95) frame.
Use NO to suppress or include a self-response to ND (Node Discover) commands. When NO bit 1 = 1, a
device performing a Node Discover includes a response entry for itself.
Parameter range
0x0 - 0x7 (bit field)