3. Remove the plastic enclosure.
4. Release the fan connector at the bottom left-hand side. To do this, press the release and
5. Carefully remove the fan from the middle plastic lug.
6. Insert the new fan and reattach the connector.
7. Check the position of the fan cables to ensure that they do not become jammed when the
8. Replace the plastic enclosure and re-engage all 7 snap hooks.
5.2.5

Replacing the CompactFlash card

If spare parts are being used, you must seek the assistance of the Technical Support Center
in order to convert the license key code of the defective CompactFlash Card to that of the
new CompactFlash Card.
Proceed as follows to write your project to the new CompactFlash Card:
● Replacing the CompactFlash Card (Page 193)
● Writing to a CompactFlash Card (Page 194)
Detailed information about licensing can be found:
● In the
● as well as In the FAQ (http://support.automation.siemens.com/WW/view/en/36947932)
SIMOTION D410
Commissioning Manual, 02/2012
The fan is located underneath the module.
the connector together gently and remove the connector.
1
Release the fan connector.
2
Remove the fan using the plastic lug.
Figure 5-3
D410, open
plastic enclosure is replaced.
SIMOTION SCOUT
5.2 Replacing modules (spare part scenario)
Configuration Manual
Maintenance and service