Download The Project To Simotion D410 - Siemens SIMOTION D410 Series Commissioning Manual

Hide thumbs Also See for SIMOTION D410 Series:
Table of Contents

Advertisement

Commissioning (software)
4.3 Performing an online configuration
Procedure
Now go ahead and adapt your components to suit the application.
Run through the wizard for all the DRIVE-CLiQ components to be adapted and perform the
required reconfigurations.
This procedure corresponds to the description in section Configuring the system in offline
mode (Page 73).
The amount of editing work involved involved depends on the components used. For
example, in the case of a motor with a DRIVE-CLiQ interface, the motor and encoder type
are identified automatically.
4.3.5

Download the project to SIMOTION D410

After you have performed the reconfigurations, you must download the configuration to the
SINAMICS Integrated.
1. Save and compile the project.
2. Go online to SIMOTION D410.
3. To download the project, execute "Download project to the target system".
4. To save the parameter calculations of the drive in the project, perform "Target device" >
90
The data must also be saved on the CompactFlash Card to ensure that the project is
retained in the event of a power failure. The following options are available:
– Perform the "Copy RAM to ROM..." function manually on the D410 and the drive
(SINAMICS Integrated).
– In the "Download to Target System" dialog box, select the option "After loading, copy
RAM to ROM". You can change the default setting for this dialog box in "Options" >
"Settings" > "Download".
"Load CPU / drive unit to PG" for the drive. Drive programming and commissioning is
completed. You can now test the drive using the drive control panel.
SIMOTION D410
Commissioning Manual, 02/2012

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotion d410 pnSimotion d410 dp

Table of Contents