Siemens SIMOTION D410 Series Commissioning Manual page 109

Hide thumbs Also See for SIMOTION D410 Series:
Table of Contents

Advertisement

1. Run through the wizard and enter the settings of your system. The required axis message
2. Click Finish to confirm the "Summary" window.
SIMOTION D410
Commissioning Manual, 02/2012
frame as well as the addresses used are automatically determined by the engineering
system. The message frame is also extended and interconnections in the drive created
automatically depending on the selected TO technology (e.g. SINAMICS Safety
Integrated).
The configured real axis is displayed in the project navigator.
Figure 4-22
Axis wizard summary
Note
During system power-up, reference variables as well as drive and encoder data of the
SINAMICS are automatically taken over for the SIMOTION configuration data of the
SIMOTION technology objects "TO axis" and "TO external encoder".
Commissioning (software)
4.6 Creating and testing an axis
109