4.10.1.2

Configuration of CU3xx/TB30/TMxx I/Os

The configuration is performed in a similar way as for the onboard I/Os X121 for the
SIMOTION D410, i.e. the I/Os can be
● BICO-interconnected (use as drive I/O)
● Used by SIMOTION
Refer also to section Configuration of SIMOTION D410 I/Os (terminal X121) (Page 128)
CAUTION
If symbolic assignment is subsequently activated for a project in which message frames
have already been configured and interconnected, these can be changed together with the
BICO interconnections.
For this reason, make a backup copy of your project before activating the symbolic
assignment.
TB30, TM15 DI/DO and TM31 are especially affected here. Refer also to section Symbolic
assignment / adaptation (Page 67).
4.10.1.3

Configuring TMC I/O terminals

The functionality of the I/O channels is configured via HW Config.
For details see
4.11

Configuring technology objects and I/O variables

4.11.1

Configuring global measuring inputs

Overview
The type of measuring input must be selected during the configuration of the TO measuring
input.
SIMOTION D410
Commissioning Manual, 02/2012
SIMOTION Terminal Modules Compact
SIMOTION Terminal Modules Compact
4.11 Configuring technology objects and I/O variables