Diagnostics data
6.1 Diagnostics by means of LED displays
Meaning
Backing up diagnostic data and non-volatile data (backup running)
Backing up diagnostic data and non-volatile data (backup completed)
Priority of the displays: The displays always visualize the state which is assigned the numerically lowest priority level.
1)
The error of the next highest priority class is displayed after the cause of the previous signal state was eliminated.
The upgrade or downgrade has been completed when the SF/BF LED goes out. The device then starts up automatically
2)
in the upgraded or downgraded configuration (the SF/BF LED display then depends on the operating mode of the
device).
The LED "OUT > 5V" display is controlled only by the encoder evaluation for the integrated
X23 encoder interface in SINAMICS Integrated. The table below lists the display states and
their meaning.
Table 6- 3
Status
0
1
(yellow)
LED in the PROFINET connector (D410 PN only)
Each of the PROFINET ports has both a green LED (LINK) and a yellow LED (ACTIVITY).
The following LED states can occur:
Table 6- 4
Name
LINK
ACT
Additional references
Detailed information can be found in the
Instructions.
200
LED display OUT > 5V
Meaning
Electronic power supply is missing or outside the valid tolerance range. Power supply
≤ 5 V. Use of an encoder with 5 V power supply.
Electronics power supply for measuring system available. Power supply >5 V.
Caution: Always ensure that you can operate the encoder on the 24 V power supply (e.g.
HTL encoder). Operating a 5 V encoder on a 24 V supply may cause its electronic
components to be destroyed. This setting can be selected in the expert list of the drive in
parameter p0405.1.
Meaning of the LED displays
Color
Status
Green
On
Yellow
Flashing
RDY
RUN/STOP
x
Λ
(yellow)
x
Λ
(green)
Meaning
A different device is connected to port x and the physical
connection exists.
Data is being received or sent at port x.
Upgrading SIMOTION Devices
OUT > 5V
SF/BF:
x
x
x
x
Operating
SIMOTION D410
Commissioning Manual, 02/2012