Creating And Testing An Axis; Overview Of Simotion Engineering - Siemens SIMOTION D410 Series Commissioning Manual

Hide thumbs Also See for SIMOTION D410 Series:
Table of Contents

Advertisement

4. Read the notes and confirm these with "Accept".
5. Activate the "Enables" checkbox to enable the drive.
6. Enter your setpoint in the input field and shift the scaling to 0% as safety setting.
Figure 4-18
7. Click the "Drive On" button. The "Enable is set" LED lights up in green color. The drive
8. Click "Drive Off" to stop the drive after you completed the test.
9. Deactivate the enable and click the "Give up control priority" button to deactivate control
4.6

Creating and testing an axis

4.6.1

Overview of SIMOTION Engineering

Performing engineering with SIMOTION SCOUT
The SIMOTION SCOUT Engineering Software is used to add axes to your project.
1. Start a session of the Axis Wizard in order to configure the axes and interconnect these
2. Provided you have completed the configuration at the drive end, we strongly recommend
SIMOTION D410
Commissioning Manual, 02/2012
All enables are now set with the exception of ON/OFF1.
Entering the setpoint
starts moving as you move the slider towards the right side. The current motor speed is
displayed in "Actual".
by the PG/PC.
with the SINAMICS Integrated drive.
for faster working that the SINAMICS Integrated is deactivated via "Target system" >
"Select target device".
Commissioning (software)
4.6 Creating and testing an axis
103

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotion d410 pnSimotion d410 dp

Table of Contents