Commissioning (hardware)
2.5 User memory concept
Reloading non-volatile SIMOTION data
SIMOTION data backed up on a CompactFlash Card with _savePersistentMemoryData is
restored in the following cases:
1. after replacing a module, refer to section Replacing modules (spare part scenario)
2. after an overall reset, refer to section Resetting the memory of SIMOTION D410
3. by switch setting, refer to section Deleting/restoring non-volatile SIMOTION data
To restore the data backed up via the Service selector switch or IT DIAG, the existing
backup files PMEMORY.XML and PMEMORY.BAK in the "USER\SIMOTION" directory on
the CompactFlash Card must be deleted. See also Section Deleting/restoring non-volatile
SIMOTION data (Page 207).
Power-up and non-volatile SIMOTION data
The table below lists the cases that can arise during power-up in conjunction with the non-
volatile SIMOTION data and explains how they are handled.
Table 2- 3
Cases: Power-up with non-volatile SIMOTION data
Cas
Initial condition
e
1
The non-volatile SIMOTION data is valid
2
The non-volatile SIMOTION data is invalid and there is
no backup file (PMEMORY.XML) and no backup copy
of the backup file (PMEMORY.BAK).
3
The non-volatile SIMOTION data is invalid and a
backup file (PMEMORY.XML) exists and is valid
4
The non-volatile SIMOTION data is invalid, the backup
file is invalid and there is no backup copy of the backup
file (PMEMORY.BAK).
5
The non-volatile SIMOTION data is invalid; a backup file
exists, but it is invalid; a backup copy of the backup file
exists and is valid.
Non-volatile SIMOTION data diagnostics
Users can determine the status of non-volatile SIMOTION data by reading the diagnostic
buffer and the system variables.
40
(Page 165).
(Page 150).
(Page 207).
Result
Startup of SIMOTION D410 with the non-volatile
SIMOTION data. The PROFIBUS address in non-volatile
data is therefore valid, for example.
SIMOTION D410 copies the factory defaults to its non-
volatile SIMOTION data and restarts using this data. The
default PROFIBUS address is valid in this case, for
example.
SIMOTION D410 copies the contents of the backup file to
its non-volatile SIMOTION data and starts using this data.
SIMOTION D410 copies the factory defaults to its non-
volatile SIMOTION data and restarts using this data. The
default PROFIBUS address is valid in this case, for
example.
SIMOTION D410 copies the contents of the backup file to
its non-volatile SIMOTION data and starts using this data.
SIMOTION D410
Commissioning Manual, 02/2012