Configuration Of Simotion D410 I/Os (Terminal X121) - Siemens SIMOTION D410 Series Commissioning Manual

Hide thumbs Also See for SIMOTION D410 Series:
Table of Contents

Advertisement

Commissioning (software)
4.10 Configuring drive-related I/Os (with symbolic assignment)
The configuration of the I/O terminals is described in detail in the following:
● Configuration of SIMOTION D410 I/Os (terminal X121) (Page 128)
● Configuration of CU3xx/TB30/TMxx I/Os (Page 129)
● Configuring TMC I/O terminals (Page 129)
4.10.1.1

Configuration of SIMOTION D410 I/Os (terminal X121)

The I/Os of terminal X121 are originally assigned to the drive unit. The configuration is
therefore performed via the drive unit ("SINAMICS_Integrated" > "Control_Unit" >
"Inputs/outputs).
The properties of the I/O channel can be configured in the parameterization dialog box. With
the bidirectional digital inputs/outputs, for example, an I/O channel can be
● parameterized as input or output
● Inverted
● BICO-interconnected (use as drive I/O)
● Used as digital input for SIMOTION with "DI (SIMOTION)"
● used as digital output for SIMOTION with "DO (SIMOTION)"
● used as global measuring input for SIMOTION with "Measuring input (SIMOTION)"
Figure 4-31
128
Configuration of D410 I/Os (terminal X121)
SIMOTION D410
Commissioning Manual, 02/2012