Leuze electronic BPS 34 Technical Description page 83

Barcode positioning system for the profibus dp
Hide thumbs Also See for BPS 34:
Table of Contents

Advertisement

Leuze
electronic
Input data
Input data
c
Signals the current state of the
internal velocity measurement
State
of the BPS 34
Input data length: 1 byte
Notice!
These input data signal the state of the BPS 34:
• Init: Base setting during initial startup of the BPS 34
• Idle: The BPS 34 is in idle state (scanning beam is off, but motor is running)
• Measure: The BPS 34 is in measurement state (data are output in module 1)
• Standby: The BPS 34 is in waiting state (laser off and motor off).
Output data
Output
data
d
Event starts velocity measure-
Start
ment.
event
Event stops velocity measure-
e
Stop event
ment.
f
Defines whether the current
Min/Max
velocity is included in min/max
velocity
recording.
mode
g
Min/Max
Reset the min/max velocity val-
velocity
ues.
reset
Output data length: 1 byte
Leuze electronic
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Description
Rel.
addr.
0
Description
Rel.
addr.
0.0
0.1
0.2
0.3
Device parameters and interfaces
Data
Value range
type
0: Init
unsign
1: Idle
8
2: Measure
4: Standby
Data
Value range
type
Bit
0 -> 1: Start
Bit
0 -> 1: Stop
0: Do not record min/max
Bit
1: Record min/max
Bit
0 -> 1: Reset
BPS 34
Default
Unit
CR to
module
0
Default
Unit
CR to
module
0
0
0
24
0
24
81