8.1.7.9 Module 9: Controller
Description
The Control module manages timing of the position calculation by starting and stopping the
decoding. Control is performed depending on certain events such as the switching input,
time functions or PROFIBUS output bits. Using parameters, the events which influence the
states are determined.
Parameter
Parameter
a
The start mode determines by
Measure-
which event the position meas-
ment start
urement is started.
mode
b
The measurement stop mode
determines after which event
Measure-
the position measurement is
ment stop
mode
stopped.
c
Time for stop timeout
Stop time-
out in [ms]
Parameter length: 4 byte
Hex coding of module 9 "Control"
The value listed in the table shows the hex coding of the default settings.
03
Leuze electronic
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Description
Rel.
addr.
0
1
2
01
04
27 10
Device parameters and interfaces
Data
Value range
type
0: Deactivated
1: After initialisation
unsign
2: By event:
8
Switching input or start event
by setting output bit 0.0
0: No function
1: After valid measurement
result
2: After timeout (stop time-
out)
3: After timeout with retrigger
(stop timeout) by setting out-
unsign
put bit 0.0 or by the switching
8
input
4: By stop event or by set-
ting output bit 0.1 or by the
switching input (the switching
input must be programmed
for this purpose)
5: By an error
unsign
0 ... 65'535
16
BPS 34
Default
Unit
CR to
module
1
7 g
4
7 g
10'000
ms
63