During mounting, the following angles of inclination must be taken into account in the vertical
axis:
10 ° for a tape height of 47 mm,
7 ° for a tape height of 30 mm and
5 ° for a tape height of 25 mm; the working range of the reading field curve must also be tak-
en into account.
Attention!
For the position calculation, the scanning beam of the BPS 34 must be incident on the bar-
code tape without interruption. Ensure that the scanning beam is always incident on the bar-
code tape when the system is moving.
Connecting the voltage supply and PROFIBUS
The BPS 34, in combination with an MS 34 103 or MS 34 105, is connected via M12
connectors.
Connecting the voltage supply
The voltage supply is connected via the PWR IN M 12 connection.
DP OUT
VCC 1
Figure 3.2:
Leuze electronic
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Socket
(A-coded)
MSD
VIN
2
/INT
/SERV
1
7
GND
6
SDA
A (N)
2
GND
3
4
PE
B (P)
Socket
(B-coded)
BPS 34 with MS 34 103/MS 34 105 - Connection PWR IN
Commissioning steps at a glance
TXD
3
RXD
4
VOUT
5
SCL
DP IN
A (N)
2
GND 3
1
4
PE
B (P)
Plug
(B-coded)
BPS 34
Socket
(A-coded)
SW IN/OUT
SWOUT
2
GND
1
3
4
PE
PWR IN
SWIN
SWOUT
3
VCC
GND
PE
(A-coded)
2
VIN
1
4
SWIN
Plug
9