Leuze electronic BPS 34 Technical Description page 90

Barcode positioning system for the profibus dp
Hide thumbs Also See for BPS 34:
Table of Contents

Advertisement

Device parameters and interfaces
8.1.7.27 Module 26: Dynamic velocity limit value
Notice!
Underlined in the CR column are the modules which must be activated in addition to the cur-
rent module.
Description
The velocity limit value function compares the current velocity with a stored velocity within
the defined range. If the value is above or below the limit value, the dynamic limit value
status in module 23 is set and, if configured, the switching output is appropriately set. Limit
value, hysteresis, range start and range end are transferred with the output data of this
module by the PROFIBUS master. The transferred values are activated by bit 0.0, i.e. if this
bit is set, the BPS 34 compares the current velocity with the new limit value conditions.
Parameter
none
Input data
none