HTU318 Device functions and indicators All settings on the sensor are taught-in via the teach button. Device status and switching states are indicated as follows by means of 3 LEDs: Switching behavior 1-point teach (1 switching point per output) Switching behavior NO contact Switching behavior NC contact Switching point Switching point...
Page 5
(blue) LEDs flash at 8Hz until an error-free teach event is performed. 1) See table "Switching behavior with 2-point window-teach as a function of the switching function" Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 HTU318-400…-M12 - 01 info@leuze.com •...
Page 6
HTU318 Adjusting the switching function (NC/NO) via the teach button The switching function of the sensor is preset as follows on delivery: OUT 1: NO contact OUT 2: NC contact The output function for each output can be individually switched from NO contact (NO - normally open) to NC contact (NC - normally closed) and vice versa.
Page 7
Sync/MUX pin 5 on all sensors in the network must be connected to one another. Generation of the synchronization signal for all sensors in the network occurs automatically. Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 HTU318-400…-M12 - 01...
Page 8
HTU318 Multiplex operation In this operating mode the mutual interference of adjacent sensors can be reliably avoided. For this purpose, up to 4 sensors of the same type are wired together in a network according to the following diagram. The devices operate in multiplex operation with a cyclically time-delayed transmission pulse and are switched to a passive state out- side of the active phase, whereby the states of the outputs are frozen until the next active phase.