Leuze electronic BPS 34 Technical Description page 70

Barcode positioning system for the profibus dp
Hide thumbs Also See for BPS 34:
Table of Contents

Advertisement

Device parameters and interfaces
8.1.7.13 Module 12: Status
Notice!
Underlined in the CR column are the modules which must be activated in addition to the cur-
rent module.
Description
This module supplies various BPS 34 status information to the PROFIBUS master.
Parameter
none
Input data
Input data
Description
Indicates that no valid integra-
a
tion value could be determined
Measure-
(measurement value prepara-
ment error
tion module).
Indicates that measurement
b
range has been exceeded
Range sta-
(measurement value acquisi-
tus
tion module)
Indicates a position-value output
c
with active static preset or
Preset
dynamic preset (Preset module)
active
Toggle bit, changes during the
d
teach event for the static and
Preset
dynamic preset value (Preset
teach
module)
e
Position
Indicates that limit value 1 has
limit value
been exceeded (measurement
status 1
value monitoring module).
(static or
dynamic)
f
Position
Indicates that limit value 2 has
limit value
been exceeded (measurement
status 2
value monitoring module).
(static or
dynamic)
g
Signals the standby status
Standby
(Control module)
status
Input data length: 1 byte
Output data
none
68
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Rel.
Data
Value range
addr.
type
0: OK
0.0
Bit
1: Error
0: OK, within measurement
range
0.1
Bit
1: Measurement range
exceeded
0: No preset active
0.2
Bit
1: Preset active
0.3
Bit
0,1: Dyn. preset teach
0: No limit value violation
0.4
Bit
1: Value greater than limit
0: No limit value violation
0.5
Bit
1: Value greater than limit
0: BPS active
0.7
Bit
1: BPS in standby
BPS 34
Leuze
electronic
Default
Unit
CR to
module
0
0
0
0
14d
0
16d
15d
0
17d
0
Leuze electronic
10
3a
4c
3a
4c
9d