Leuze electronic BPS 34 Technical Description page 63

Barcode positioning system for the profibus dp
Hide thumbs Also See for BPS 34:
Table of Contents

Advertisement

Leuze
electronic
8.1.7.8 Module 8: Switching output
Notice!
Underlined in the CR column are the modules which must be activated in addition to the cur-
rent module.
Description
The module defines the mode of operation of the digital switching output.
Parameter
Parameter
a
The parameter defines the DC bias
DC bias
level of the switching output.
level
Defines whether the switching out-
b
put is controlled by
static velocity limit value 1,
static velocity limit value 2,
Velocity
static velocity limit value 3,
limit value
static velocity limit value 4
selection
or the
dynamic velocity limit value
The parameter defines the switch-on
c
time period for the switching output. If
Pulse dura-
the value is 0, the signal is static.
tion in [ms]
d
The parameter defines the events
which set the switching output:
- velocity valid
- velocity not valid
- position limit value 1 reached
- position limit value 1 not reached
- outside measurement range
Switch-on
- inside measurement range
function
- position limit value 2 reached
[ON]
- position limit value 2 not reached
- erroneous measurement
- successful measurement
- PROFIBUS positive edge
- PROFIBUS negative edge
- velocity limit value reached
- velocity limit value not reached
Leuze electronic
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Description
Device parameters and interfaces
Rel.
Data
Value range
addr.
type
unsign
0: LOW (0 V)
0
8
1: HIGH (+U
1.0
1.1
for each
1.2
Bits
0: No
1.3
1: Yes
1.4
unsign
2
0 ... 1'300
16
4.0
4.1
4.2
4.3
4.4
for each
4.5
Bits
0: Not active
4.6
1: Active
4.7
5.2
5.3
5.4
5.5
5.6
5.7
BPS 34
Default
Unit
0
)
B
0
0
0
0
0
400
ms
0
0
0
0
0
0
0
0
1
0
0
0
0
0
CR to
module
25 for
static
26 for
dynamic
22
22
14 + 16
14 + 16
10
10
15 + 17
15 + 17
1 + 9
1 + 9
8
8
25
25
61