Leuze electronic BPS 34 Technical Description

Leuze electronic BPS 34 Technical Description

Barcode positioning system for the profibus dp
Hide thumbs Also See for BPS 34:
Table of Contents

Advertisement

Quick Links

Leuze
electronic
Barcode positioning system BPS 34
for the PROFIBUS DP
Technical Description
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com

Advertisement

Table of Contents
loading

Summary of Contents for Leuze electronic BPS 34

  • Page 1 Leuze electronic Barcode positioning system BPS 34 for the PROFIBUS DP Technical Description Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 2 © All rights reserved, especially the right of reproduction and translation. This document may not be duplicated or reproduced in any form without the written permission of Leuze electronic GmbH + Co. KG It is subject to changes due to technical progress.
  • Page 3: Table Of Contents

    Table of contents General information ......................3 Explanation of symbols ......................3 Declaration of conformity ..................... 3 Description of the BPS 34 functions ..................4 Safety notices........................5 General safety notices ......................5 Safety standards ........................5 Intended use ........................5 Working safely ........................
  • Page 4 Diagnostics and troubleshooting................... 92 General causes of errors ....................92 PROFIBUS errors ......................92 Type overview and accessories ..................94 10.1 Type overview: BPS 34...................... 94 10.2 Accessory modular hoods with integrated connectors............94 10.3 Accessory modular service display..................94 10.4...
  • Page 5: General Information

    MS 34 103/MS 34 105, and the optional modular service display MSD 1 101 have been developed and manufactured under observation of the applicable European standards and directives. The devices of the BPS 34 series also fulfil the cUL requirements (Underwriters Laboratory Inc.) for the USA and Canada. Notice! A copy of all declarations of conformity available for the product can be found in the appen- dix of this handbook (see chapter 12.1 "EU Declaration of Conformity"...
  • Page 6: Description Of The Bps 34 Functions

    General information Description of the BPS 34 functions The BPS 34 uses visible red laser light to determine its position relative to the barcode tape. This essentially takes place in three steps: Reading a code on the barcode tape...
  • Page 7: Safety Notices

    BPS 34 in a PROFIBUS system. The modular service display MSD 1 101, which is optionally available, displays operational data of the BPS 34 and is used as a simple means of access to the service interface of the MS 34 105.
  • Page 8: Working Safely

    The output power of the laser beam at the reading window is at most 1.8 mW acc. to EN 60825-1. The BPS 34 uses a laser diode with low power in the visible red light range with an emitted wavelength of 650 … 690 nm.
  • Page 9 Leuze electronic Safety notices The barcode positioning system BPS 34 is provided with the following warning notices on the housing, as well as below and next to the reading window: AVOID EXPOSURE- LASER LIGHT IS EMITTED FROM THIS APERTURE CAUTION: LASER LIGHT IF OPEN...
  • Page 10: Commissioning Steps At A Glance

    Commissioning steps at a glance Notice! Below you will find a short description for the initial commissioning of the barcode po- sitioning system BPS 34. Detailed explanations for all listed points can be found throughout the handbook. ➀ Mechanical design...
  • Page 11 ➁ Connecting the voltage supply and PROFIBUS The BPS 34, in combination with an MS 34 103 or MS 34 105, is connected via M12 connectors. Connecting the voltage supply The voltage supply is connected via the PWR IN M 12 connection.
  • Page 12 (B-coded) (A-coded) Figure 3.3: BPS 34 with MS 34 103/MS 34 105 - Connections DP IN and DP OUT Setting the PROFIBUS address The PROFIBUS address must be set in the MS 34 10x connector plug hood. The correct address setting on the PROFIBUS network is indicated by the green LED on the MS 34 10x.
  • Page 13 Commissioning steps at a glance PROFIBUS manager Install the GSE file associated with the BPS 34… in the PROFIBUS manager of your control. Activate the desired modules (at least module 1 - position value). Figure 3.5: Example PROFIBUS manager Store the slave address for the BPS 34 in the PROFIBUS manager.
  • Page 14 Figure 3.7:BPS 34 with MS 34 103/MS 34 105 - Connection MSD The BPS 34 can be accessed via the MS 1 101 using the service interface. Notice! Changes which were made via the service interface on the BPS 34 are lost following initial- isation on the PROFIBUS. BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 15: Specifications Bps 34

    Leuze electronic Specifications BPS 34 Specifications BPS 34 General specifications BPS 34 Optical data Light source Laser diode 650 nm Beam deflection by means of rotating polygon mirror wheel Reading distance see reading field (figure 4.3.5) Optical window glass with scratch-resistant Indium coating Laser safety class 2 acc.
  • Page 16: Dimensioned Drawings

    For devices with integrated heating (…H models), window heating is in constant operation. Regulation of device-internal heating is temperature dependent. Dimensioned drawings BPS 34 SM 100 / BPS 34 SM 100 H / BPS 34 SM 100 HT Rear view Plan view...
  • Page 17 Specifications BPS 34 MS 34 103 / MS 34 105 MS 34 103 MS 34 105 Notice! A = BPS 34 The MSD and SW IN/OUT All dimensions in mm connections are sealed with caps upon delivery. Figure 4.2:Dimensioned drawing MS 34 103 / MS 34 105...
  • Page 18: Electrical Connection

    Specifications BPS 34 Electrical connection The BPS 34 can be connected via the MS 34 103/MS 34 105 using M12 connectors. For the locations of the individual device connections, please refer to the device detail shown in figure 4.3.
  • Page 19 Plug (B-coded) (B-coded) (A-coded) Figure 4.3:Connection assignment of the BPS 34 with MS 34 103 / MS 34 105 Attention! Protection class IP 65 is achieved only if the connectors and caps are screwed into place! Leuze electronic BPS 34...
  • Page 20: Pwr In - Voltage Supply And Switching Input/Output

    Pin assignment PWR IN Connection of the functional earth PE BPS 34 including hood with integrated connectors MS 34 103/MS 34 105: ! Connect PE to PIN 5 of the M 12 connector PWR IN for the voltage supply! Notice! Programming of the switching input/switching output is performed via module 7 (Switching input) and module 8 (Switching output).
  • Page 21: Dp In - Profibus Dp Incoming

    Leuze electronic Specifications BPS 34 4.3.2 DP IN - PROFIBUS DP incoming DP IN (5-pin plug, B-coded) Name Remark DP IN 5 V DC for bus termination A (N) A (N) Receive/transmit data A-line (N) Functional earth for bus termination...
  • Page 22: Sw In/Out - Switching Input/Switching Output

    Leuze electronic Specifications BPS 34 4.3.4 SW IN/OUT - switching input/switching output SW IN/OUT (5-pin socket, A-coded) Name Remark Supply voltage for sensors SW IN/OUT SWOUT (VOUT identical to VIN at PWR IN) VOUT without optics heating: +10 … +30 V DC with optics heating: +22 …...
  • Page 23: Bps 34 Reading Field Curve

    Leuze electronic Specifications BPS 34 Connecting the switching input / switching output The BPS 34 is provided with a switching input and a switching output. The connection is performed as shown in figure 4.8: Connector SW IN/OUT SWIN V OUT...
  • Page 24: Connector Units Ms 34

    A modular hood of type MS 34 103 or MS 34 105 with integrated connectors is part of every BPS 34. The two hoods with integrated connectors are used to connect the BPS 34 to the PROFIBUS. For this, they feature one DP IN and one DP OUT connection each, as well as switches for address setting.
  • Page 25: Dimensioned Drawings

    Connector units MS 34 … / MSD 1 101 5.1.3 Dimensioned drawings MS 34 103 MS 34 105 A = BPS 34 Notice! The MSD and SW IN/OUT All dimensions in mm connections are sealed with caps upon delivery.
  • Page 26: Electrical Connection

    PROFIBUS, error cannot be resolved by a reset of the control orange, continuous light service operation active Note: The LED remains off until the BPS 34 is recognised by the PROFIBUS. Only after the PROFIBUS has addressed the BPS 34 for the first time, the following status descrip- tions apply.
  • Page 27: Modular Service Display Msd 1 101

    The RS 232 service interface of the BPS 34 is located on the 9-pin sub-D connector of the MSD. To connect the MSD 1 101 to the MS 34 105, an 8-pin cable (M 12) with a length of 2 m is used (see chapter 10.3 "Accessory modular service display").
  • Page 28: Dimensioned Drawing

    MSD 1 101 and is designed as a 9-pin sub-D connector. The pin configuration of the 9- pin sub-D connector corresponds to a standard RS 232 interface: • PIN 2 = RxD • PIN 3 = TxD • PIN 5 = GND BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 29: Barcode Tape

    Figure 6.1: Roll with barcode tape Features: • Robust and durable polyester adhesive tape • High dimensional stability • Max. length 10’000 m • Self-adhesive, high adhesive strength Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 30: Specifications Of The Barcode Tape

    DIN 30646 Curing final curing after 72 h, the position can be detected imme- diately by the BPS 34 after the BCT is affixed Thermal expansion due to the high elasticity of the BCT, thermal expansion of...
  • Page 31: Mounting The Barcode Tape

    BPS. The gap must not be greater than the distance from one cut mark to the next (max. one label). max. 40 mm 000020 000024 000028 000032 000036 Cut mark Figure 6.3: Gap in the cut barcode tape Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 32 If the scanning beam cannot completely scan any label, the BPS 34 returns the value 0. As soon as the BPS 34 can again scan a complete label, it calculates the next position value.
  • Page 33 BCT is affixed without ten- sion (see figure 6.3). 007000 Figure 6.4: Partial cutting of the barcode tape in curves Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 34: Control Barcode

    BPS 34. Notice! The control of functions using control barcodes is a new feature of the BPS 34. The imple- mentation of additional control options via control barcodes is in preparation.
  • Page 35: Controllable Functions

    If the centre of the BPS 34 reaches the transition point of the control barcode, the device switches to the second tape, provided the next position label is in its scanning beam.
  • Page 36 (see figure 6.8). In this situation, the hysteresis of ±5 mm is irrelevant. If, however, the device is stopped within the hysteresis on the "MVS" label and the direction changed, the starting position values have an inaccuracy ±5 mm. BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 37: Repair Kit

    If only the "MVS" label is located in the scanning beam, the voltage on the BPS 34 must not be switched off. Otherwise the BPS 34 will return a position value of zero when the voltage is switched back on.
  • Page 38 4 cm. Figure 6.9: Printer settings for BCT repair kit 40 mm 000020 000024 000028 000032 000036 Figure 6.10: Checking the print results of the BCT repair kit BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 39: Mounting

    BPS 34 mounting options BT 56 mounting device The BT 56 mounting device is available for mounting the BPS 34 using the fastening grooves. It is designed for rod installation (Ø 16 mm to 20 mm). For ordering instructions, please refer to chapter 10.6 on page 94.
  • Page 40 Ø 16 … 20 mm All dimensions in mm A Rod holder, turnable 360 ° B Rods Ø 16 … 20 mm Figure 7.2: BT 56 mounting device BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 41 Attention! For the position calculation, the scanning beam of the BPS 34 must be incident on the bar- code tape without interruption. Ensure that the scanning beam is always incident on the bar- code tape when the system is moving.
  • Page 42: Device Arrangement

    • On the BPS 34, the beam is not emitted perpendicular to the cover of the housing, but with an angle of 10 ° towards the top. This angle is intended to prevent total reflection on the barcode tape.
  • Page 43: Mounting The Barcode Tape

    • mount in such a way that the device is protected from relative wind; mount additional shields if necessary. Notice! When installing the BPS 34 in a protective housing, it must be ensured that the scanning beam can exit the protective housing without obstruction. Mounting the barcode tape The BPS 34 and barcode tape combination is mounted in such a way that the scanning beam is unobstructed and is incident on the barcode tape as described in figure 7.4 on...
  • Page 44: Device Parameters And Interfaces

    8.1.1 General information The BPS 34 with MS 34 103/MS 34 105 is designed as a PROFIBUS device (PROFIBUS DP-V0 acc. to IEC 61784-1) with a baud rate of 12 MBd. The functionality of the device is defined via parameter sets which are clustered in modules. These modules are contained in a GSE file.
  • Page 45 Thread Functional earth (housing) (B-coded) Figure 8.3: Pin assignment DP IN Attention! Protection class IP 65 is achieved only if the connectors and caps are screwed into place! Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 46 For connecting DP IN and DP OUT, we recommend our ready-made PROFIBUS cables. For further information, see chapter 10.8 on page 96. The BPS 34 can be used in combination with an MS 34 103/MS 34 105 to branch out the PROFIBUS network. The continuing network is connected via DP OUT.
  • Page 47: Profibus Address

    You can find the GSE file at Leuze website -> Download -> Logistics -> Optical barcode positioning. This file stores all the data required for the operation of the BPS 34. This data consists of device parameters required for operation of the BPS 34 and the definition of the control and status bits.
  • Page 48: Structure Of The Gse Modules

    The BPS 34 does not permanently store parameters changed via the PROFIBUS. Following Power off/on, the currently configured parameters are downloaded from the PROFIBUS manager. If no PROFIBUS manager is available following Power OFF/ON, the BPS 34 ac- tivates its stored default settings.
  • Page 49: Overview Of The Gse Modules

    Measurement value (P) Maximum permitted measurement length acquisition (P) Minimum permitted measurement length page 65 Measurement value (P) Integration depth preparation (O) Count direction for position calculation page 66 Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 50 Velocity (I) Current velocity page 77 (P) Resolution (P) Scaling factor Velocity parameters (P) Integration depth page 78 (P) Tolerance time (on error message) (P) Error output delay BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 51 (O) Hysteresis (O) Range start (O) Range end (P) Actual length Tape value correction (P) Range start page 90 (P) Range end Table 8.1: Overview of the GSE modules Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 52: Detailed Description Of The Modules

    The parameters and input/output data within a module are alphanumerically labelled from … Example: Static preset value in [mm] parameter in module 3 becomes active only when the preset teach occurs via module 12 or 3 BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 53 (for a resolution in mm) value Input data length: 4 byte Notice! A negative number is represented in the input data by a 1 in the most significant bit. Output data none Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 54 Device parameters and interfaces 8.1.7.2 Module 2: Resolution Description With this module, the resolution for the position value of module 1 is defined. The BPS 34 also performs a rounding correction (The position value is divided by the defined value range).
  • Page 55 The preset remains stored in the BPS 34 and remains active even following a new start. In order for the BPS 34 to again output the position value without the preset, bit 0.1 in the output data must be set.
  • Page 56 Read in the preset value 0->1 = Teach – – Preset teach Preset value is deactivated. 0->1 = Reset – – Preset reset Output data length: 1 byte BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 57 BPS 34 and remains active even following a new start. In order for the BPS 34 to again output the tape value, bit 0.1 in the output data must be set (preset reset). The preset value is transmitted to the BPS 34 together with the output data of the PROFIBUS master.
  • Page 58 Hex coding of module 5 "Offset value" The value listed in the table shows the hex coding of the default settings. 00 00 00 00 Input data none Output data none BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 59 • Hysteresis of dynamic position limit values 1 and 2 (modules 16 and 17) The static preset or dynamic preset modules (module 3 or module 4) are not affected by the scaling. Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 60 Hex coding of module 6 "Scaling" The value listed in the table shows the hex coding of the default settings. 03 E8 Input data none Output data none BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 61 0 … 65’535 – delay in [ms] The parameter defines the mini- mum pulse duration of the input signal. unsign 0 … 65’535 – Pulse dura- tion in [ms] Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 62 State of the signal of the switch- 0: Input not active – – State ing input 1: Input active Input data length: 1 byte Output data none BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 63 1 + 9 - successful measurement 1 + 9 - PROFIBUS positive edge - PROFIBUS negative edge - velocity limit value reached - velocity limit value not reached Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 64 PROFIBUS edge configured. Output data length: 1 byte Notice! With the "PROFIBUS edge" function, the switching output can be directly activated or deac- tivated by setting bit 0.0. BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 65 [ms] Parameter length: 4 byte Hex coding of module 9 "Control" The value listed in the table shows the hex coding of the default settings. 27 10 Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 66 Notice! The standby function can only be activated while in "Measure" state. This function switches off the motor and laser. It takes approx. 2 sec. to switch the BPS 34 back on (valid measure- ment values at the interface) In "Idle" state, the motor continues to run. Only the laser is switched off. It takes approx.
  • Page 67 8.1.7.10 Module 10: Measurement value acquisition Description With this module, a working range on the barcode tape can be defined. The BPS 34 outputs position values within these minimum and maximum limits. Outside of these limits, a position value of zero is output.
  • Page 68 In order to obtain positive or negative position values depending on the direction of move- ment of the BPS 34, the count direction can be selected as normal or inverted in the output data of this module.
  • Page 69 Output data length: 1 byte Notice! The BPS 34 is set as follows by default: The position value is output with "normal" count direction. With the "inverted" count direction, 10’000’000 mm minus the position value is output. This behaviour can be influenced using the "Static preset"/"Dynamic preset"...
  • Page 70 8.1.7.13 Module 12: Status Notice! Underlined in the CR column are the modules which must be activated in addition to the cur- rent module. Description This module supplies various BPS 34 status information to the PROFIBUS master. Parameter none Input data Input data Description Rel.
  • Page 71 Parameter length: 2 byte Hex coding of module 13 "Min/Max position" The value listed in the table shows the hex coding of the default settings. Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 72 With "MinMax reset", the input data are reset to 155812h. With this module, the settings for the Preset (module 3), Offset (module 5) and Scaling (module 6) modules must be taken into account. BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 73 Output data none Notice! With this module, the settings for the Preset (module 3), Offset (module 5) and Scaling (module 6) modules must be taken into account. Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 74 Output data none Notice! With this module, the settings for the Preset (module 3), Offset (module 5) and Scaling (module 6) modules must be taken into account. BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 75 1 in module 12 is set and, if configured, the switching output is appropriately set. The limit value is transferred to the BPS 34 together with the output data of this module by the PROFIBUS master.
  • Page 76 2 in module 12 is set and, if configured, the switching output is appropriately set. The limit value is transferred to the BPS 34 together with the output data of this module by the PROFIBUS master.
  • Page 77 The availability of the system is thereby ensured. No new values are delivered by the BPS 34, however, for a period of time extending up to the config- ured tolerance time. With the "delay error output" parameter, an integration error (corre- sponds to a missing position value) can be signalled immediately or after the tolerance time has elapsed.
  • Page 78 8.1.7.20 Module 19: Service Description The "service" function is used to reset the parameter set of the BPS 34 to default settings. This reset only occurs directly in the BPS 34. After the reset function has been activated, the device carries out a reset and is freshly configured on the PROFIBUS. This results in the reactivation of all modules and parameter settings selected in the PROFIBUS project.
  • Page 79 Outputs the current velocity with the configured resolution and the desired scaling factor. In order for the velocity to be calculated in the BPS 34 and output in this module, module 22 (Control velocity) must also be activated in the PROFIBUS project.
  • Page 80 0: No, error delay deactivated Delay veloc- error by the configured toler- – 1: Yes, error delay activated ity error out- ance time. Parameter length: 7 bytes BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 81 Hex coding of module 21 "Velocity parameters" The value listed in the table shows the hex coding of the default settings. 03 E8 00 32 Input data none Output data none Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 82 Parameter length: 2 byte Hex coding of module 22 "Velocity measurement" The value listed in the table shows the hex coding of the default settings. BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 83 • Init: Base setting during initial startup of the BPS 34 • Idle: The BPS 34 is in idle state (scanning beam is off, but motor is running) • Measure: The BPS 34 is in measurement state (data are output in module 1) •...
  • Page 84 Leuze electronic Device parameters and interfaces 8.1.7.24 Module 23: Velocity measurement status Description This module supplies various status information regarding the velocity measurement of the BPS 34 to the PROFIBUS master. Parameter none Input data Input data Description Rel. Data...
  • Page 85 The "Dynamic preset" module (module 4), the "MVS label" function and the "error tolerance time" can be used to activate the messages of the input data. Depending on the con- … figuration, these may be normal states. Output data none Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 86 0 … 10’000’000 scaled Minimum period. velocity Maximum velocity for detected unsign 0 … 10’000’000 scaled Maximum period. velocity Input data length: 8 byte Output data none BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 87 Velocity 0 … 20’000 mm/s current velocity. limit value 1 in [mm/s] Relative offset of switching unsign Velocity 0 … 20’000 mm/s point. hysteresis 1 in [mm/s] Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 88 [mm] The velocity limit value is moni- Range end sign32 -10’000’000 … 10’000’000 tored up to this position. limit value 4 in [mm] Parameter length: 50 bytes BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 89 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Input data none Output data none Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 90 PROFIBUS master. The transferred values are activated by bit 0.0, i.e. if this bit is set, the BPS 34 compares the current velocity with the new limit value conditions. Parameter...
  • Page 91 [mm] The dynamic velocity limit Range end value is monitored up to this sign32 -10’000’000 … 10’000’000 dyn. limit position. value in [mm] Output data length: 13 byte Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 92 The tape value is corrected with the real length up to this posi- sign32 0 … 10’000’000 10’000’000 – Range end tion. in [mm] Parameter length: 10 bytes BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 93 The value listed in the table shows the hex coding of the default settings. 27 10 00 00 00 00 00 98 96 80 Input data none Output data none Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 94: Diagnostics And Troubleshooting

    LED MS 34 10x = the BPS 34 is recognised by the "off" PROFIBUS. Only after the PROFIBUS has addressed the BPS 34 for the first time do the following status descriptions apply. ❏ LED MS 34 10x = • Error on the PROFIBUS.
  • Page 95 Customer data (please complete) Leuze service fax number: +49 7021 573-199 Device type: Company: Contact partner / department: Phone (direct): Fax: Street / No: ZIP code/City: Country: Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 96: Type Overview And Accessories

    Part No. Type designation Remark 50037230 MS 34 103 Modular hood with integrated connectors for BPS 34 with three M 12 connectors 50037231 MS 34 105 Modular hood with integrated connectors for BPS 34 with five M 12 connectors 10.3 Accessory modular service display Part No.
  • Page 97: Accessory Ready-Made Cables For Voltage Supply

    M 12 socket for PWR IN, axial connector, open line end, cable length 5 m 50104559 K-D M12A-5P-10m-PVC M 12 socket for PWR IN, axial connector, open line end, cable length 10 m Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 98: Accessory Ready-Made Cables For Profibus Connection

    B (P) M 12 plug (B-coded) 1 Conductor with insulation red 2 Conductor with insulation green 3 Drain wire 4 Fibrous fleece Figure 10.1:Cable structure of PROFIBUS connection cable BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 99: 10.8.3 Specifications Of Profibus Connection Cable

    M 12 plug, M 12 socket for PROFIBUS, axial connectors, cable length 25 m 50104173 KB PB-30000-SBA M 12 plug, M 12 socket for PROFIBUS, axial connectors, cable length 30 m Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 100: Type Overview: Barcode Tape

    BCB / special lengths starting at 150 m Barcode tape with special length and special height 50102600 BCB special length 25 mm high Barcode tape with special length 25 mm high BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 101: Maintenance

    11.1 General maintenance information Usually, the BPS 34 does not require any maintenance by the operator. In the event of dust build-up, clean the optical window with a soft cloth; use a cleaning agent (commercially available glass cleaner) if necessary.
  • Page 102: Appendix

    Leuze electronic Appendix Appendix 12.1 EU Declaration of Conformity BPS 34 Leuze electronic Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 103 Dimensioned drawings ..... . . 14 BPS 34 Cable ..... 15 MS 34 105 .
  • Page 104 ..... . . 37 BPS 34 ......37 BT 56 .
  • Page 105 ..17 ....13 Protection class Optical data Leuze electronic BPS 34 Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com...
  • Page 106 ......94 BPS 34 ....46 Universal module .