Controllable Functions - Leuze electronic BPS 34 Technical Description

Barcode positioning system for the profibus dp
Hide thumbs Also See for BPS 34:
Table of Contents

Advertisement

Leuze
electronic
For error-free function, when using control barcodes it must absolutely be ensured that the
distance between the BPS and barcode tape is selected large enough. The scanning beam
of the BPS should cover three or more barcodes; this is ensured at a distance which lies in
the working range of the reading field curve.
The control barcodes are simply affixed over the existing tape. When affixing the control
barcodes, make certain to cover entire barcodes to ensure that a barcode spacing of 4 cm
is maintained.
Figure 6.6:
6.4.1

Controllable functions

Measurement value switching between 2 barcode tapes with different value
ranges
The "MVS" control barcode is used to switch between two barcode tapes. The end of one
tape and the start of the next can end and begin, respectively, with completely different posi-
tion barcodes. If the centre of the BPS 34 reaches the transition point of the control barcode,
the device switches to the second tape, provided the next position label is in its scanning
beam. As a result, the output position can always be uniquely associated with one tape.
Leuze electronic
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Correct positioning of the control barcode
Control barcode cor-
rectly affixed on the
barcode tape
Control barcode in-
correctly affixed on
the barcode tape
BPS 34
Barcode tape
33