  • Page 1 EN 2015/06 - 50129340 We reserve the right to make technical changes...
  • Page 2 © 2015 Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen / Germany Phone: +49 7021 573-0 Fax: +49 7021 573-199 http://www.leuze.com info@leuze.de Leuze electronic ODS 10...
  • Page 3: Table Of Contents

    ≤eaching the switching outputs ......... . . 30 Leuze electronic ODS 10...
  • Page 4 14.1 ≤ype overview ODS 10 ........
  • Page 5: About This Document

    Optical Distance Sensor OLED Organic Light Emitting Diode Organic LED PELV Protective Extra Low Voltage Protective extra low voltage with reliable disconnection ≤OF ≤ime-of-Flight Distance measurement procedure using the propagation time of the signal ≥L ≥nderwriters Laboratories Leuze electronic ODS 10...
  • Page 6: Important Terms

    ≤he output resolution describes how the measurement values are pre- sented on the display and digital interfaces. ≤he output resolution of the ODS 10 is 1 mm and cannot be changed. Delay before start-up ≤he delay before start-up indicates the point in time when the first valid measurement can be obtained after switching on.
  • Page 7: Safety

    ≤he protection of personnel and the device cannot be guaranteed if the device is operated in a manner not complying with its intended use. Leuze electronic GmbH + Co. KG is not liable for damages caused by improper use.  Read these original operating instructions before commissioning the device.
  • Page 8: Exemption Of Liability

    (e.g. electrician foreman). In other countries, there are respective regulations that must be observed. Exemption of liability Leuze electronic GmbH + Co. KG is not liable in the following cases: • ≤he device is not being used properly. • Reasonably foreseeable misuse is not taken into account.
  • Page 9: Device Description

    ≤he measurement time is set via the display and control panel or by means of configuration software. Advantages of the time-of-flight measurement principle: • Large measurement range • Low influence of gloss and structures on the measurement value Leuze electronic ODS 10...
  • Page 10: Performance Characteristics

    Device description 3.1.3 Performance characteristics ≤he most important performance characteristic of the ODS 10 laser distance sensor: • Large measurement range • 50 mm … 8000 mm against objects (90% diffuse reflection) • 100 mm … 25000 mm using reflective tape •...
  • Page 11: Indicators And Operational Controls

    3.3.4 "Meaning of the display icons". Navigating within the menus ≥se the navigation button to move through the menu. Activate the desired selection with the enter button Leuze electronic ODS 10...
  • Page 12: Display

    • Arrow pointing upward: the current measurement value is larger than the upper limit of the analog output. 3.3.4 Meaning of the display icons ≤he buttons have different functions depending on the operating situation. ≤hese functions are displayed via icons at the right edge of the display. Leuze electronic ODS 10...
  • Page 13: Configuration / Menu Structure

    For information on the meaning of the display icons, see chapter 3.3.4. 3.4.1 Input menu ≤he function of the switching input on pin 5 is set in the Input menu. ≤he Input menu is only available for sensors with switching input. Leuze electronic ODS 10...
  • Page 14: Menu Output Q1

    3.4.3 Menu Output Q2 ≤he switching behavior of switching output Q2 on pin 5 is set in the Output Q2 menu. ≤he Output Q2 menu is only available for sensors with a second switching output Q2. Leuze electronic ODS 10...
  • Page 15: Analog Output Menu

    It is also possible to invert the working range of the analog switching output, i.e., the lower limit of the measurement range is set to a larger value than upper limit. ≤his creates a descending characteristic output curve. Leuze electronic ODS 10...
  • Page 16: Application Menu

    In the table, you will find an overview of how the choice of measure mode affects the individual parameters of the measurement function. ≤able 3.2: Measure mode and measurement function parameter Measure mode Accuracy Measurement time Measurement value update Standard 20 ms Precision 50 ms Speed 3.5 ms Leuze electronic ODS 10...
  • Page 17: Settings Menu

    ≤o illustrate menu operation, the setting of the lower switching point of switching output Q1 to 100 mm is explained as an example.  In process mode, press a control button to activate the menu display. Input Output Q1  Press the navigation button ≤he display shows Output Q1 in the upper menu line. Leuze electronic ODS 10...
  • Page 18  Repeat the setting for the other digits until the complete value 00100 is set. ≥se the enter button to switch from one digit to the next. Q1 Lower Sw. Pt. 00100 mm Leuze electronic ODS 10...
  • Page 19  Press the navigation button repeatedly until ← Menu Exit appears in the upper menu line. <-- Menu Exit Input  Press the enter button to exit the menu display and access process mode. 225 mm Leuze electronic ODS 10...
  • Page 20: Function And Applications

    • High-bay storage device: push-through protection; see chapter 4.1 • Crane: collision protection; see chapter 4.2 • Stack height measurement; see chapter 4.3 • Loop measurement; see chapter 4.4 Push-through protection Figure 4.1: High-bay storage device: push-through protection Leuze electronic ODS 10...
  • Page 21: Collision Protection

    Function and applications Collision protection Figure 4.2: Crane: collision protection • Measurement against reflective tape (ODS 10L1-25M*), 100 mm … 25000 mm Leuze electronic ODS 10...
  • Page 22: Stack Height Measurement

    Function and applications Stack height measurement Figure 4.3: Stack height measurement Leuze electronic ODS 10...
  • Page 23: Loop Measurement

    Function and applications Loop measurement Figure 4.4: Loop measurement Leuze electronic ODS 10...
  • Page 24: Mounting

     Mount the sensor on the machine with M4 fastening screws (not included in delivery contents). Max. tightening torque of the fastening screws: 1.4 Nm For space-saving installation of the sensor, both sides of the housing are provided with recesses for M4 inlay nuts. Depth of the recesses: 4.2 mm. Leuze electronic ODS 10...
  • Page 25: Electrical Connection

    Configurable analog output • Current: 4 mA … 20 mA • Voltage: 1 V … 10 V, 0 V … 10 V Factory setting: Current Functional earth IO-Link / switching output 1, push-pull Function of the switching input Leuze electronic ODS 10...
  • Page 26 Pin assignment Designation Assignment 18-30 V DC + Supply voltage 4-20 mA Configurable analog output • Current: 4 mA … 20 mA • Voltage: 1 V … 10 V, 0 V … 10 V Factory setting: Current Leuze electronic ODS 10...
  • Page 27 Electrical connection Designation Assignment Functional earth IO-Link / switching output 1, push-pull Switching output 2, push-pull Leuze electronic ODS 10...
  • Page 28: Commissioning - Sensors With Analog Interface

    I [mA] U [V] ca. 24 ca. 11 ca 2.5 25000 25500 ca. 30000 ≥ndefined range Linearity undefined Measurement range Object present No object detected Measurement distance Figure 7.1: Behavior of analog output ODS10L1-25M.8/L (factory setting) Leuze electronic ODS 10...
  • Page 29: Eaching The Analog Output

    Corresponds to 1 V or 4 mA on the analog output (pin 5) Distance value for the end of the measurement range 220 ms … 280 ms Corresponds to 10 V or 20 mA on the analog output (pin 5) Leuze electronic ODS 10...
  • Page 30: Setting The Switching Outputs

    Configuration of the switching output(s) is performed using the OLED display and the keyboard (see Sensor Studio chapter 3.4) or using the configuration software (see chapter 9). 7.2.2 ≤eaching the switching outputs You can set switching points, hysteresis and switching behavior for the switching outputs via the configu- ration menu. Leuze electronic ODS 10...
  • Page 31 ≤he teach point lies in the middle of the switching range. If a measurement distance of e.g. 1000 mm is now taught, the switching output Q1 switches on at 950 mm and back off at 1050 mm. Leuze electronic ODS 10...
  • Page 32: Setting Measure Mode

    Standard 20 ms Precision 50 ms Speed 3.5 ms Reset to factory settings Configuration is performed using the OLED display and the keyboard (see chapter 3.4) or using the Sensor Studio configuration software (see chapter 9). Leuze electronic ODS 10...
  • Page 33: Commissioning - Sensors With Io-Link Interface

    1: running measurement (measurement running) 0: during start-up, teaching, deactivation 1: signal OK, reception signal is sufficient for measurement value output 1: warning; e.g., weak reception signal Q1 … Q3 Switching states Q1, Q2, Q3 1: active Leuze electronic ODS 10...
  • Page 34: Connecting To A Pc - Sensor Studio

     Install the driver for the IO-Link ≥SB master on the PC.  Connect the IO-Link ≥SB master to the PC.  Connect the OSD 10 (IO-Link device) to the IO-Link ≥SB master.  Install IO-Link device D≤M with IODD file for ODS 10 in the Sensor Studio FD≤ frame.
  • Page 35: Installing Sensor Studio Configuration Software And Io-Link ≥Sb Master

    If FD≤ frame software is already installed on your PC, you do not need the instal- lation. You can install the communication D≤M (IO-Link ≥SB master) and the device D≤M (IO-Link device ODS 10) in the existing FD≤ frame. Leuze electronic ODS 10...
  • Page 36: Installing Drivers For Io-Link ≥Sb Master

    Internet: www.leuze.com > Products > Measuring Sensors > Distance Sensors > Optical Distance Sensors > ODS 10 > Downloads tab > Software/Drivers  Copy the file into a suitable folder on your hard drive and unpack the zip file.
  • Page 37: Installing The D≤M And Iodd

     Select the IO-Link device D≤M (≥ser Interface) installation option and follow the instructions on the screen. ≤he Installation Wizard installs the D≤M and the IO Device Description (IODD) for the sensor. D≤M and IODD for all IO-Link devices currently available from Leuze electronic are installed. Sensor Studio Starting the...
  • Page 38 Sensor Studio In the FD≤ frame, click on the [Online parameters] button ( ≤he IO-Link ≥SB master synchronizes with the connected sensor and the current configuration data and measurement data are displayed in the device manager (D≤M). Leuze electronic ODS 10...
  • Page 39: Short Description Of The Sensor Studio Configuration Software

    ≤his chapter contains information and explanations on the individual menu items and adjustment param- Sensor Studio eters of the configuration software and the device manager (D≤M) for the ODS 10 distance sensor. Sensor Studio ≤his chapter does not include a complete description of the configuration soft- ware.
  • Page 40: Fd≤ Frame Menu

    • Device information, e.g., designation, order no., serial number, etc. • Information on the IO-Link parameters of the connected sensor, e.g., Device ID, cycle time, etc. • ≤echnical description of the connected sensor • Data sheet of the connected sensor Leuze electronic ODS 10...
  • Page 41: Config≥Ra≤Ion Function

    Connecting to a PC – Sensor Studio CONFIG≥RA≤ION 9.4.3 function CONFIG≥RA≤ION Figure 9.5: function • Set the measure mode: • Precision • Standard • Speed • Set the analog output functions • Configuration of the digital switching inputs/outputs Leuze electronic ODS 10...
  • Page 42: Process Function

    • Visualization of the distance value and the states of the digital output signals. ≤ext-based display of the current values: PROCESS Figure 9.7: function – distance value and status • Graphical display of the recorded measurement values, including the history: Leuze electronic ODS 10...
  • Page 43 Connecting to a PC – Sensor Studio PROCESS Figure 9.8: function – display of the measurement values PROCESS Figure 9.9: function – display of the measurement values Leuze electronic ODS 10...
  • Page 44: Diagnosis Function

     Exit the program via File > Exit.  Save the configuration settings as a configuration project on the PC. Sensor Studio You can open the configuration project again at later time via File > Open or via the Project Wizard ( Leuze electronic ODS 10...
  • Page 45: Roubleshooting

    DIAGNOS≤ICS menu, and rectify the error. NO≤ICE Contact Leuze electronic subsidiary/customer service.  If you are unable to rectify a fault, contact the Leuze electronic branch responsible for you or call the Leuze electronic customer service (see chapter 12 "Service and support"). 10.2 LED indicators You can use the LED indicators to ascertain general causes of errors;...
  • Page 46 Signal Error Signal failure If the icon is displayed continuously: con- Wrench icon Sensor defective tact Leuze electronic customer service (see chapter 12 "Service and support") Down arrow ≤he current measurement value is Change the setting for the lower limit of...
  • Page 47: Care, Maintenance And Disposal

    ≤he device does not normally require any maintenance by the operator. Repairs to the device must only be carried out by the manufacturer.  For repairs, contact your responsible Leuze electronic subsidiary or Leuze electronic customer service (see chapter 12 "Service and support").
  • Page 48: Service And Support

    Repair service and returns: Procedure and Internet form can be found at www.leuze.com/repair Return address for repairs: Service Center Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen / Germany 12.1 What should I do if service is required? NO≤ICE...
  • Page 49: Echnical Data

    Luminosity coefficient 6% … 90% ≤emperature drift ±2 mm/K ≤able 13.3: ≤iming Measurement time Operating mode • Fast : 3.5 ms • Standard : 20 ms • Precision : 50 ms Factory setting Delay before start-up 300 ms Leuze electronic ODS 10...
  • Page 50 Connection cable, 200 mm, with M12 connector ≤able 13.7: Environmental data Ambient temperature (operation) -40 °C … +50 °C Ambient temperature (storage) -40 °C … +70 °C Protective circuit ≤ransient protection Polarity reversal protection Short circuit protection for all outputs Leuze electronic ODS 10...
  • Page 51: Dimensioned Drawings

    IP 67 Standards applied IEC 60947-5-2 13.2 Dimensioned drawings Ø 4,2 25,5 45,5 all dimensions in mm Reference edge for the measurement Optical axis M12 connector, turnable 90° Figure 13.1: Dimensioned drawing ODS 10 with M12 connector Leuze electronic ODS 10...
  • Page 52: Dimensioned Drawings: Accessories

    ≤echnical data 13.3 Dimensioned drawings: Accessories all dimensions in mm Figure 13.2: Dimensioned drawing mounting system B≤≥ 300M-D10/D12/D14 all dimensions in mm Figure 13.3: Dimensioned drawing mounting bracket B≤ 300M.5 Leuze electronic ODS 10...
  • Page 53: Ordering Information And Accessories

    Ordering information and accessories Ordering information and accessories 14.1 ≤ype overview ODS 10 Optical distance sensors, measurement against object • Maximum measurement range: 8000 mm • Connection: M12 connector, 5-pin Part no. Part designation Description 50127853 ODS10L1.8/LAK-M12 IO-Link 1.1, analog output, multifunction input,...
  • Page 54: Accessories - Cables And Connectors

    5-pin, M12, axial, length 5 m 14.3 Other accessories ≤able 14.2: Other accessories Part no. Part designation Description 50111527 REF 7-A-100x100 Reflective tape, self-adhesive, 100 mm x 100 mm 50117251 B≤≥ 300M-D14 Mounting system for mounting on rods Ø 14 mm Leuze electronic ODS 10...
  • Page 55: 14.3.1 Accessories - Pc Connection

    High-speed ≥SB 2.0 connection cable; ≥SB A to Mini-≥SB Data carrier with software, drivers and documenta- tion 50110126 K-DS M12A-M12A-4P-2m-PVC Interconnection cable with M12 connector on both ends, 4-pin, M12, axial, length 2 m, PVC sheath- Leuze electronic ODS 10...
  • Page 56: Ec Declaration Of Conformity

    EC Declaration of Conformity EC Declaration of Conformity ≤he optical distance sensor systems of the ODS 10 series were developed and manufactured in accor- dance with the applicable European standards and directives. ≤he manufacturer of the product, Leuze electronic GmbH + Co. KG in D-73277 Owen, possesses a certi- fied quality assurance system in accordance with ISO 9001.