Electrical Connection; Description Of The Led States - Leuze electronic BPS 34 Technical Description

Barcode positioning system for the profibus dp
Hide thumbs Also See for BPS 34:
Table of Contents

Advertisement

Connector units MS 34 ... / MSD 1 101
5.1.4

Electrical connection

Electrical data
Interface type
Service interface
Switching input / output
Operating voltage
Power consumption
1)
Only in combination with the MS 34 105 and MSD 1 101 devices
5.1.5

Description of the LED states

MS 34 103 / MS 34 105
At the modular hood with integrated connectors a status LED is located between the M 12
connectors DP IN and DP OUT. It indicates the state of the PROFIBUS connection.
State
off
green flashing
green, continuous light
red, flashing
red, continuous light
orange, continuous light
2)
Note: The LED remains off until the BPS 34 is recognised by the PROFIBUS. Only after
the PROFIBUS has addressed the BPS 34 for the first time, the following status descrip-
tions apply.
24
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
PROFIBUS DP, up to 12 MBd
1)
RS232 with default data format,
9600 Bd, 8 data bits, no parity, 1 stop bit
1 switching input, 1 switching output, each is programmable
without optics heating:
with optics heating:
without optics heating:
with optics heating:
Meaning
voltage off or device not yet recognised by the PROFIBUS
initialisation of the device, establishing the PROFIBUS communication
data operation
error on the PROFIBUS, error can be resolved by a reset of the control
error on the PROFIBUS, error cannot be resolved by a reset of the control
service operation active
BPS 34
Leuze
electronic
10 ... 30 V DC
22 ... 26 V DC
5 W
max. 30 W
2)
Leuze electronic