8.1.7.17 Module 16: Dynamic position limit value 1
Description
The limit value function compares the position value with a stored position. If the value is
above or below the limit value, the limit value status 1 in module 12 is set and, if configured,
the switching output is appropriately set.
The limit value is transferred to the BPS 34 together with the output data of this module by
the PROFIBUS master.
Parameter
Parameter
a
Parameter activates limit value
Limit value
checking.
mode 1
Condition for the signal change
b
of the switching output/status
Switching
bit.
mode 1
c
Relative offset of switching
Hysteresis 1
point.
in [mm]
Parameter length: 4 byte
Hex coding of module 16 "Dynamic position limit value 1"
The value listed in the table shows the hex coding of the default settings.
0F
Input data
none
Output data
Output data
d
Limit value is compared to the
Limit value 1
current position value.
in [mm]
Output data length: 4 byte
Notice!
With this module, the settings for the Preset (module 3), Offset (module 5) and Scaling
(module 6) modules must be taken into account.
Leuze electronic
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Description
Rel.
addr.
0
1
2
00
00
00 00
Description
Rel.
addr.
0
Device parameters and interfaces
Data
Value range
type
unsign
0: Off
8
1: On
unsign
0: Value greater than limit
8
1: Value less than limit
unsign
0 ... 65'535
16
Data
Value range
type
sign32 -10'000'000 ... 10'000'000
BPS 34
Default
Unit
CR to
module
0
7 g
8d
0
12e
0
mm
Default
Unit
CR to
module
0
mm
73