Table 4-5
Peripheral
Shelf Unit: PI Parameters
4-26
Software Installation Procedure
Parameter
SHELVES [0]
ACTIVE_UNIT [1]
(The following parameters are displayed only if the Unit is physically installed)
PB_STATUS#1 [2]
PB_STATUS#2 [3]
PB_SELECT [4]
POWER_SUPPLY_
STATUS #1 [5]
POWER_SUPPLY_
STATUS#2 [6]
RING_POWER_SUPPLY_
STATUS #1 [7]
RING_POWER_SUPPLY_
STATUS #2 [8]
NUMBER_OF_TIME_
SLOTS [9]
UNIT_TYPE [10]
Send To 32GC Card? [11]
Range
Description
(0,1) to
Displays the number of the system shelves
(14,15)
that define this Peripheral Shelf Unit.
Read-Only
Yes/No
If the UNIT is installed (i.e. a PB-ATS card is
Read-Only
installed on the even shelf), then the system
sets this parameter to Yes, defining this
Peripheral Shelf Unit as an Active Unit.
Exists
Displays the status of the PB-ATS card
No Card
installed in Slot 1/2. Both PB-ATS cards are
No Clock
located on the even shelf.
PCM Fault
If no PB-ATS card is installed, then the
Read-Only
parameter displays No Card.
If the card exists and is not functioning
properly, then the parameter displays either
No Clock or PCM Fault depending on the
fault.
1 - Slot 1
Describes which PB-ATS card is Active for
this unit. The technician may change this
2 - Slot 2
value.
This parameter is used when the technician
must remove a faulty card. Before removing
the faulty card, a working PB-ATS card must
be defined in this parameter.
OK
Displays the status of the displayed item.
Faulty
Read-Only
128
Defines the number of time slots for this Unit.
512
The number of time slots is factory set and
cannot be changed. This number can also be
Read-Only
viewed on the PB-ATS front panel.
0-Normal
Define this Unit as a Normal (Local Unit) or a
1-Remote
Remote Coral FlexLITE unit.
Yes/No
Loads the modified UNIT information. When
No is entered, updates are ignored and the
system remains at its pre-programmed
definitions.