Step 1 Perform a pre-replacement check.
Check whether there is a redundant power module and whether the Running/
Alarm indicator of the redundant power module is steady green, as shown in
Figure
Running/Alarm Indicators on a 2 U Controller
Figure 6-22 Running/Alarm indicator on a power module
You can perform replacement only when a redundant power module exists and
the redundant power module is working properly.
Issue 15 (2019-12-30)
Before replacing a power module, ensure that the other power module is
working properly.
One BBU is installed in each power module. When a power module is being
replaced, ensure that the BBU in the other power module is working correctly.
Do not touch the connectors of a power module and a power cable.
Remove and insert a power module with even force. Excessive force may
damage the appearance or connectors of the power module.
Remove only one power module at a time.
A power module must be replaced within three minutes. Otherwise, the
system heat dissipation is compromised.