Figure 7-86 Installing an 8 Gbit/s Fibre Channel interface module (eight ports) (6
U controller enclosure as an example)
Step 10 Wait two minutes and then check the status of the Power indicator on the 8
Gbit/s Fibre Channel interface module (eight ports) to determine whether the
interface module has been successfully installed.
of the indicator.
Issue 15 (2019-12-30)
If the indicator is steady green, the interface module has been successfully
installed.
If the indicator is steady red or off, the newly installed interface module is
faulty, the interface module slot is faulty, or the interface module is
incorrectly installed.