Replacing A System Subrack (For 5500 V5/5500F V5) - Huawei OceanStor V5 Series Parts Replacement

Hide thumbs Also See for OceanStor V5 Series:
Table of Contents

Advertisement

OceanStor V5 Series
Parts Replacement
3.
----End
Follow-up Procedure
After the system subrack is replaced, label it to facilitate subsequent operations.

7.3.2 Replacing a System Subrack (for 5500 V5/5500F V5)

This section describes how to replace a system subrack.
Impact on the System
Replacing a system subrack interrupts services running on the system subrack.
Perform this operation with caution and under the guidance of technical support
engineers.
Prerequisites
Precautions
Tools and Materials
Issue 15 (2019-12-30)
After the preceding procedure is complete, check services on the host for
storage-related errors.
The spare part is on hand.
The system subrack that you want to replace has been located.
You can locate a component in one of the following ways:
● Locating a component based on alarms in DeviceManager: On the Alarms and Events
page of DeviceManager, view the help information and determine the ID of the
component to be replaced. Then locate the component at your site based on its ID.
● Locating a component based on its location indicator: You are advised to set the
location indicator of the component in DeviceManager. For details, see the
of DeviceManager. Then, locate the component at your site based on its location
indicator.
● Locating a component based on the status of its Running/Alarm indicator: For details
about the indicators on different components, see Indicator Introduction of each
Product Description specific to your product model and version.
component in the
The cable connection positions of the system subrack that you want to
replace are labeled on the cables.
Services running on the system subrack that you want to replace have been
stopped.
Remove and insert a system subrack with even force. Excessive force may
damage the appearance or connectors of the system subrack.
It is recommended that three persons are present when moving a fully
configured system subrack to prevent personal injury.
Phillips screwdrivers (M3 to M6)
ESD wrist strap
Copyright © Huawei Technologies Co., Ltd.
7 Replacing FRUs
Online Help
165

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Oceanstor v500r007

Table of Contents