Figure 7-70 Indicators on an assistant cooling unit
Step 9 Confirm the replacement.
1.
2.
3.
----End
Follow-up Procedure
After the assistant cooling unit is replaced, label it to facilitate subsequent
operations.

7.6 Replacing a Cable

This section describes how to replace a cable.
7.6.1 Replacing an MPO-4*DLC Optical Fiber (for 8 Gbit/s
Fibre Channel Interface Module (Eight Ports)/16 Gbit/s Fibre
Channel Interface Module (Eight Ports))
This section describes how to replace an MPO-4*DLC optical fiber.
Impact on the System
During the replacement of an MPO-4*DLC optical fiber, the system switches
services from the fibers (four array ports) to other ports on this controller or on
the peer controller. If available links are unable to bear the current service load,
host latency increases and the system performance degrades. If there are no
redundant links, services carried by the optical fiber will be interrupted.
Issue 15 (2019-12-30)
Perform a post-replacement inspection.
After the parts replacement, return to the SmartKit page and click Replaced.
Then complete the parts check after the replacement as prompted.
Check system status.
On the Parts Replacement page, click Inspection to check the system status
again. If any item fails inspection, rectify the fault based on the suggestions in
the inspection report.
After the preceding procedure is complete, check services on the host for
storage-related errors.