Huawei OceanStor V5 Series Parts Replacement page 182

Hide thumbs Also See for OceanStor V5 Series:
Table of Contents

Advertisement

OceanStor V5 Series
Parts Replacement
1.
2.
3.
Figure 7-38 Installing a system subrack
Step 9 Connect cables to the system subrack and press the Power button to power on the
storage device.
Step 10 When the Power indicator is steady on, check whether each component is in
normal state.
Step 11 Confirm the replacement.
1.
2.
3.
----End
Issue 15 (2019-12-30)
Slide the system subrack into the cabinet along guide rails.
Use M6 screws to fix the system subrack in the cabinet.
Ensure that the system subrack is horizontally installed and tightly screwed.
If yes, the system subrack has been successfully installed.
If no, cables are incorrectly connected, components are incorrectly installed, or
the newly installed system subrack is faulty.
Perform a post-replacement inspection.
After the parts replacement, return to the SmartKit page and click Replaced.
Then complete the parts check after the replacement as prompted.
Check system status.
On the Parts Replacement page, click Inspection to check the system status
again. If any item fails inspection, rectify the fault based on the suggestions in
the inspection report.
After the preceding procedure is complete, check services on the host for
storage-related errors.
Copyright © Huawei Technologies Co., Ltd.
7 Replacing FRUs
173

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Oceanstor v500r007

Table of Contents