3.
Step 3 Wait until the disk indicator turns normal, indicating that the disk is powered on.
----End
Follow-up Procedure
Log in to the quorum server.
1.
2.
Issue 15 (2019-12-30)
Figure 7-112 Installing a disk
Ensure that the ejector lever is fastened to the chassis beam, and lower the
ejector lever to completely insert the spare part into the chassis. See step (2)
in
Figure
7-112.
Run the qsadmin command to check whether the configuration page of the
quorum server software is displayed.
Q2qumrom:~ # qsadmin
start main!
Waiting for connecting to server...
admin:/>
If the preceding command output is displayed, go to 2.
If the preceding command output is not displayed, the arbitration
configuration information has been lost. In this case, reinstall and
configure the quorum server software.
For details, see the
DCs)
.
Run the show server_ip command to check whether the connection between
the quorum server and storage devices is in Established state.
admin:/>show server_ip
Index
Server IP
Server Port
-----
---------------
---------------
1
192.168.6.31
30002
2
192.168.7.31
30002
Index
Local IP
Local Port
-----
---------------
---------------
0
192.168.6.31
30002
1
192.168.6.31
30002
2
192.168.7.31
30002
3
192.168.7.31
30002
If yes, the quorum server can work properly.
If no, check whether the IP address of the quorum server is correct.
Copyright © Huawei Technologies Co., Ltd.
BC&DR Solution Product Documentation (Active-Active
Remote IP
---------------
---------------
192.168.6.17
192.168.6.18
192.168.7.16
192.168.7.28
7 Replacing FRUs
Remote Port
State
---------
44510
Established
36836
Established
57416
Established
49752
Established
257

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Oceanstor v500r007

Table of Contents