TraceWakeUp determines how frequently the configured SKF Multilog WVT
automatically samples the selected trace values. As part of the Trace Route, you
may select to measure acceleration FFT and/or time, velocity FFT, and bearing FFT
and/or time.
Select the TraceWakeUp interval in number of minutes, hours, or days, up to one
month, in between the times when the SKF Multilog WVT will take the specified
time wave and spectra measurements. The options for the TraceWakeUp interval
are the same as TrendWakeUp interval. The default is one day.
SKF Multilog On-line System WVT
User Manual
 All of the intervals that are less than one day are divided exactly
over a 24 hour period; therefore, if the sample is taken at 2 p.m.
on one day, it remains at 2 p.m. on all days.
Figure 7 - 10.
Device Settings, TrendWakeUp Options.
Figure 7 - 11.
Device Settings, TraceWakeUp Options.