Replacing A Power Supply - Avaya S8800 Manual

Hide thumbs Also See for S8800:
Table of Contents

Advertisement

Replace the Avaya S8800 Server and its components
Verify RAID status:
1. On the SMI, click Diagnostics > RAID Status.
2. On the RAID Status page, verify that the status of the two hard drives is reported.

Replacing a power supply

Removing a power supply
About this task
Caution:
To remove all electrical current from the server, ensure that all power cords are disconnected
from the power source. The power control button on the server does not turn off the electrical
current supplied to the server. The server also might have more than one power cord.
Caution:
Never remove the cover on a power supply or any part that has the following label
attached.
36
Maintaining the Avaya S8800 Server for Avaya Aura
To do so:
• In the Device Present>Physical Devices section of the RAID Status page,
verify the following values:
Disks : 2
Failed Disks : 0
Note:
Make sure that the entries indicate that both the hard drives are physically
installed in the server and are not in a failed status.
• At the bottom of the RAID Status page, verify that the RAID Status page
displays entries for the two hard drives similar to the following:
Device (Encl-252 Slot-0) is not in rebuild process
Device (Encl-252 Slot-1) is not in rebuild process
Note:
The entries for the two hard drives can also indicate that one of the drives
is in the rebuild process.