Chapter 9: Building Stacks with Multi-Gigabit Copper Ports
Table 13. Configuring the Master Switch for a Stack Trunk of Multi-Gigabit Copper Ports - Part II
Step
9
Restart the switch with the REBOOT command.
awplus# reboot
reboot system? (y/n):
10
Type "Y" for yes.
11
Wait one minute for the switch to start the AlliedWare Plus software.
12
Go to "Verifying the Master Switch" on page 128.
Verifying the
Master Switch
awplus# show stack
Virtual Chassis Stacking summary information
ID Pending ID
1
-
2
-
3
-
4
-
Operational Status
Stack MAC address
128
Description and Command
To confirm the configuration of the master switch, perform the following
steps:
1. Start a new local management session on the master switch. Refer to
"Starting a Local Management Session" on page 102.
2. Move to the Privileged Exec mode with the ENABLE command.
awplus> enable
awplus#
3. Enter the SHOW STACK command. Figure 67 is an example of a
master switch with three provisioned member switches:
MAC address
nnnn.nnnn.nnnn
-
-
-
Figure 67. SHOW STACK Command on the Master Switch
4. Check the display for the following:
Switch ID 1 is the master switch.
The other ID entries are the provisioned member switches that you
added. There should be one entry for each member switch that will
be in the stack. If the table does not include these fields, perform
the SWITCH PROVISION command in "Configuring the Master
Switch - Part II" on page 126.
Priority
Status
1
Ready
-
-
-
-
-
-
Standalone unit
nnnn.nnnn.nnnn
Role
Active Master
Provisioned
Provisioned