3 Parameter Description
22-86 Speed at Design Point [Hz]
Range:
Application
[Application dependant]
dependent*
3
22-87 Pressure at No-Flow Speed
Range:
0.000 N/A*
[Application dependant]
par. 22-82 Work Point Calculation
Please see also
22-88 Pressure at Rated Speed
Range:
999999.999
[Application dependant]
N/A*
par. 22-82 Work Point Calculation
Please see also
22-89 Flow at Design Point
Range:
0.000 N/A*
[0.000 - 999999.999 N/A]
par. 22-82 Work Point Calculation
Please see also
22-90 Flow at Rated Speed
Range:
0.000 N/A*
[0.000 - 999999.999 N/A]

3.21 Main Menu - Time-based Functions - Group 23

3.21.1 23-0* Timed Actions
Timed Actions
Use
for actions needing to be performed on a daily or weekly basis, e.g. different references for working hours / non-working hours. Up
to 10 Timed Actions can be programmed in the frequency converter. The Timed Action number is selected from the list when entering parameter group
23-0* from the LCP. Par. 23-00
ON time and an OFF time, in which two different actions may be performed.
The actions programmed in Timed Actions are merged with corresponding actions from digital inputs, control work via bus and Smart Logic ControllerLogic
Controller, according to merge rules set up in 8-5*O-5#, Digital/Bus.
NB!
The clock (parameter group 0-7*) must be correctly programmed for Timed Actions to function correctly.
216
Function:
Resolution 0.033 Hz.
Only visible when par. 22-82
which the System Design Working Point is achieved should be entered here in Hz. Alternatively, the
speed in RPM can be entered in par. 22-85
use Hz in par. 0-02
Function:
Enter the pressure H
point D.
Function:
Enter the value corresponding to the Pressure at Rated Speed, in Reference/Feedback Units. This
value can be defined using the pump datasheet.
point A.
Function:
Enter the value corresponding to the Flow at Design Point. No units necessary.
point C.
Function:
Enter the value corresponding to Flow at Rated Speed. This value can be defined using the pump
datasheet.
ON Time
– par. 23-04
Occurrence
then refer to the selected Timed Action number. Each Timed Action is divided into an
MG.11.C9.02 - VLT
VLT
Work Point Calculation
is set to
Speed at Design Point [RPM]
Motor Speed Unit
Speed at No-Flow [RPM]
, then par. 22-83
corresponding to Speed at No Flow in Reference/Feedback Units.
MIN
®
is a registered Danfoss trademark
®
HVAC Drive Programming Guide
Disable
. The speed of the motor at
. If it has been decided to
should also be used.