Proxim ORiNOCO AP-800 Software Management Manual page 40

Hide thumbs Also See for ORiNOCO AP-800:
Table of Contents

Advertisement

TPC (Transmit Power
Control) Back-off
Cell Size
®
ORiNOCO
802.11n Access Points - Software Management Guide
The AP device transmits maximum output power, as per the selected frequency and country
(regulatory domain). With TPC Back-off, you can adjust the output power of the AP device
to a lower level, in order to reduce the interference with the neighboring devices or to use a
higher gain antenna without violating the maximum radiated output power allowed for your
regulatory domain.
By default, it is set to 0 dBm. To configure, enter a value ranging from 0 to 25 dBm in the
TPC Back-off box.
:
TPC Back-off range (0-25 dBm) varies for different cell sizes (Large, Medium, Small,
Micro and Mini).
Specifies the parameter that enables you to control the coverage area of the AP device in
different types of deployment scenarios. For instance, usage of small cell size in dense device
deployment, minimizes the interference caused by one device on another.
Cell sizes supported by the AP device are Large, Medium, Small, Micro and Mini. By default,
it is Large. To configure, select the Cell Size from the drop down menu.
It is classified for different VAP types (See
defining the relation between transmit power, receive sensitivity and CCA threshold
associated with different Cell Sizes.
Type
AP Cell Size Functionality
Cell Size Functionality
Virtual Access Point
Description
When the cell size is set to Large, the transmit power and
receive sensitivity are high. When the Cell Size is set from
Large to Micro, Mini, Small or Medium, the transmit power
is reduced.
Data tabulated below explains the AP Cell Size Functionality
for different Cell Sizes.
Cell Size
Maximum Tx
Power*
(dBm)
Large
Maximum
TxPower
Medium
Maximum
TxPower-3
Small
Maximum
TxPower-6
Micro
Maximum
TxPower-9
Mini
Maximum
TxPower-12
* Maximum transmit power depends on the selected frequency
domain and type of radio card.
Device Configuration
(VAP), for details),
Receive
Clear Channel
Sensitivity
Assessment
Threshold
Threshold (dBm)
(dBm)
-96
-62
-86
-62
-78
-52
-70
-42
-62