HTTP Interface /
Telnet Interface
Does Not Work
Not able to login
into the CLI, after
the unit is rebooted
Telnet CLI Does Not
Work
TFTP Server Does
Not Work
Unable to Retrieve
Event Logs through
HTTPS
®
ORiNOCO
802.11n Access Points - Software Management Guide
Make sure you are using a compatible browser:
— Microsoft Internet Explorer 7.0 or later
— Mozilla Firefox 3.0 or later
Make sure you have the proper IP address of device. Enter the device IP address in the
address bar of the browser, for example http://169.254.128.132.
When the Enter Network Password window appears, enter the User Name and
enter the HTTP password in the Password field. The default HTTP username is admin
and password is public.
Use CLI, to check the IP Access Table which can restrict access to Telnet and HTTP.
Though the CLI prompts for the username and password, the device will take two minutes to
get initialized and accept the login credentials, after rebooting it.
Make sure you have the proper IP address. Enter the device IP address in the Telnet
connection dialog, from a DOS prompt: C:\> telnet <Device IP Address>
Use HTTP, to check the IP Access Table which can restrict access to Telnet and HTTP.
: Please enable Telnet in Vista or Windows 7 as it is by default disabled.
With TFTP, you can transfer files to and from the device. If a TFTP server is not properly
configured and running, you cannot upload and download files. The TFTP server:
Can be situated either local or remote
Must have a valid IP address
Must be set for send and receive without time-out
Must be running only during file upload and download
If the TFTP server does not upload or download files, it could mean:
The TFTP server is not running
The IP address of the TFTP server is invalid
The upload or download directory is not correctly set
The file name is not correct
:
• Ensure, the firewall on the Ethernet PC is disabled until the TFTP process is completed.
• Also ensure that the IP Address configured on the server and the wireless client are the
same, by checking the IP Address at the bottom right corner of the TFTP Server.
If using Internet Explorer 7 and are not able to retrieve event logs through HTTPS, do the
following:
1. Open Internet Explorer
2. Navigate to Tools > Internet Options > Advanced
3. Go to Security and uncheck/deselect Do not save encrypted pages to disk
Alternatively, use Mozilla Firefox 3.5 or later.