Specify Display Panel Variables - Emerson 5301HxxxxxxxxxxxxxxZZ Series Reference Manual

Guided wave radar level transmitter
Table of Contents

Advertisement

Reference Manual
00809-0100-4530
Table 6-1: LCD Parameters and Presentation on Display
Parameter
Analog output current
Percent range
Interface level
Interface distance
Interface level rate
Interface signal strength
Volume lower
Volume upper
Upper product thickness
Signal quality
Surface/noise margin
Vapor DC
6.3

Specify display panel variables

6.3.1
Specify display panel variables using Rosemount Radar
Master
Specify variables and corresponding measurement units to be presented on the display
panel (LCD) screen:
Procedure
1. Select Setup → General, or select the General icon in the Device Config window.
Reference Manual
Presentation on display
ANOUT
%RANGE
IFLVL
IFDIST
IFRATE
IFAMPL
VOL LO
VOL UP
UPTKNS
SIG Q
SNM
VAP DC
Operation
April 2019
(continued)
Description
4 -20 mA current
Level value in percent of total
measurement range
Level of the lower product
Distance between the upper
reference point and the
interface between the upper
and lower product
The speed of interface level
movement up or down
The signal amplitude of the
interface echo
Product volume of lower
product
Product volume of upper
product
Thickness of the upper product
The signal quality
The relationship between the
surface peak amplitude and the
strongest noise peak amplitude
The vapor dielectric constant