Emerson 5301HxxxxxxxxxxxxxxZZ Series Reference Manual page 293

Guided wave radar level transmitter
Table of Contents

Advertisement

Reference Manual
00809-0100-4530
Table A-10: Ambient Temperature Limits
Description
Option code BR5 with integral
display
(1)
Integral display may not be readable and device display updates will be slower at temperatures
below -4 °F (-20 °C).
A.2.10
Flange rating
The flanges, except the Fisher
materials 316, 316L, and EN 1.4404.
ASME flange rating
316 up to Class 1500 flanges according to ASME B16.5 Table 2-2.2 and 316L for Class 2500
flanges according to ASME B16.5 Table 2-2.3:
Standard: Max. 302 °F/580 psig (150 °C/40 Bar)
HP: Class 2500 up to max 482 °F (250 °C)
C: Class 2500 up to max 392 °F (200 °C)
HTHP: Class 2500 up to max 752 °F (400 °C)
Alloy C-276 (UNS N10276) according to ASME B16.5 Table 2-3.8:
Standard: Max. 302 °F/580 psig (150 °C/40 Bar)
HP: Class 1500 up to max 482 °F (250 °C)
HTHP: Class 1500 up to max 752 °F (400 °C)
Duplex 2205 (UNS S31803) according to ASME B16.5 Table 2-2.8:
Standard: Max. 302 °F/580 psig (150 °C/40 Bar)
HP: Class 1500, -51 °F (-46 °C) up to max 482 °F (250 °C)
HTHP: Class 1500, -51 °F (-46 °C) up to max 599 °F (315 °C)
EN flange rating
EN 1.4404 according to EN 1092-1 material group 13E0:
Standard: Max. 302 °F/580 psig (150 °C/40 Bar)
HP: PN 320 up to max 482 °F (250 °C)
C: PN 320 up to max 392 °F (200 °C)
HTHP: PN 320 up to max 752 °F (400 °C)
Alloy C-276 (UNS N10276) according to EN 1092-1 material group 12E0:
Standard: Max. 302 °F/580 psig (150 °C/40 Bar)
HP: PN 320 up to max 482 °F (250 °C)
HTHP: PN 320 up to max 752 °F (400 °C)
Reference Manual
(continued)
Operating limit
-67 °F to 158 °F (-55 °C to 70
(1)
°C)
and Masoneilan
flanges, are triple certified for the
Specifications and reference data
Storage limit
-76 °F to 185 °F (-60 °C to 85 °C)
April 2019
293

Hide quick links:

Advertisement

Table of Contents
loading