Emerson 5301HxxxxxxxxxxxxxxZZ Series Reference Manual page 278

Guided wave radar level transmitter
Table of Contents

Advertisement

Specifications and reference data
April 2019
Figure A-4: Accuracy Over Measuring Range for Single Lead Probes (Rigid/Segmented Rigid/Flexible)
3.9 in. (10 cm)
9.8 in. (25 cm)
0.4 in. (1 cm)
A. Water (DC = 80)
B. Oil (DC = 2)
C. Accuracy
D. Blind Zone
Figure A-5: Accuracy Over Measuring Range for Twin Lead Probes
3.9 in. (10 cm)
9.8 in. (25 cm)
0.8 in. (2 cm)
A. Water (DC = 80)
B. Oil (DC = 2)
C. Accuracy
D. Blind Zone
278
A
±
±
0.12 in.
1.18 in.
(3 mm)
(30 mm)
C
A
±
±
0.12 in.
1.18 in.
(3 mm)
(30 mm)
C
B
±
±
0.12 in.
(3 mm)
(30 mm)
3.5 in. (9 cm)
9.8 in. (25 cm)
4.7 in. (12 cm)
B
±
±
0.12 in.
(3 mm)
(30 mm)
3.2 in. (8 cm)
8.3 in. (21 cm)
4.7 in. (12 cm)
Reference Manual
00809-0100-4530
1.18 in.
C
D
1.18 in.
C
D
Rosemount 5300 Level Transmitter

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents