Shorten The Probe - Emerson 5301HxxxxxxxxxxxxxxZZ Series Reference Manual

Guided wave radar level transmitter
Table of Contents

Advertisement

Mechanical installation
April 2019
Figure 3-17: Low-Low Unit
A. UNZ = 14 in. (350 mm)
B. Minimum 20 in. (500 mm)
C. 20 mA
D. 4 mA
E. Warning
F. Shutdown
3.2.12
Shipboard installations
Transmitters with aluminum housing are not approved for open deck installations.
For application conditions and limitations refer to the applicable shipboard approval.
3.3

Shorten the probe

3.3.1
Shorten the flexible single/twin lead probe
Prerequisites
Note
The PTFE covered probes must not be cut in field.
Make sure that at least 1.6 in. (40 mm) of the cable is inserted when the weight is
replaced.
44
Reference Manual
00809-0100-4530
Rosemount 5300 Level Transmitter

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents