Configuration
April 2019
5.12
HART
The Rosemount 5300 Series Transmitter can be run in multidrop mode. In the multidrop
mode each transmitter has a unique HART address.
Figure 5-9: Multidrop Connection
5.12.1
Change the poll address using Rosemount Radar Master
To set the desired address for multidrop operation:
Procedure
1. Select Setup → General.
2. Select the Communication tab.
3. Set the desired address for multidrop operation.
4. Click the Store button to save the new address.
156
®
multi-drop configuration
HART 5: addresses between 1 and 15
HART 7: addresses between 1 and 63