Canada - Emerson 5301HxxxxxxxxxxxxxxZZ Series Reference Manual

Guided wave radar level transmitter
Table of Contents

Advertisement

Reference Manual
00809-0100-4530
Special Conditions for Safe Use (X):
1. WARNING – Potential Electrostatic Charging Hazard – The enclosure contains non-
2. WARNING – The apparatus enclosure contains aluminum and is considered to
FISCO parameters
B.6

Canada

B.6.1
E6 Explosionproof, Dust-Ignitionproof
Certificate 1514653
Standards CSA C22.2 No.0-M91, CSA C22.2 No.25-1966, CSA C22.2 No.30-M1986,
Markings
B.6.2
I6 Intrinsically Safe and Non-Incendive Systems
Certificate 1514653
Standards CSA C22.2 No.0-M91, CSA C22.2 No.25-1966, CSA C22.2 No.30-M1986,
Markings
Entity parameters HART 30 V
Entity parameters
Fieldbus
B.6.3
IF FISCO
Certificate 1514653
Reference Manual
metallic material. To prevent the risk for electrostatic sparking the plastic surface
should only be cleaned with a damp cloth.
constitute a potential risk of ignition by impact or friction. Care must be taken into
account during installation and use to prevent impact or friction.
Ui
17.5 V
CSA C22.2 No.94-M91, CSA C22.2 No.142-M1987, CSA C22.2 157-92,
CAN/CSA C22.2 No. 60529:05, ANSI/ISA 12.27.01-2003
Explosionproof CL I, DIV 1, GP B, C, D; Dust-Ignitionproof CL II, DIV 1 and 2,
GP E, F, G and coal dust, CL III, DIV 1, Type 4X/IP66/IP67
CSA C22.2 No.94-M91, CSA C22.2 No.142-M1987, CSA C22.2 157-92,
CAN/CSA C22.2 No. 60529:05, ANSI/ISA 12.27.01-2003
CL I, DIV 1, GP A, B, C, D, T4 see installation drawing 9240030-937; Non-
Incendive Class III, DIV 1, Haz-loc CL I DIV 2, GP A, B, C, D, Maximum
Ambient Temperature +60 °C for Fieldbus and FISCO and +70 °C for HART,
T4, Type 4X/IP66/IP67, Maximum Working Pressure 5000 psi, Dual Seal.
Ui
30 V
Ii
Pi
380 mA
5.32 W
Ii
Pi
130 mA
1 W
300 mA
1.3 W
Product certifications
April 2019
Ci
Li
0
0
Ci
Li
7.26 nF
0
0
0