Reference Manual
00809-0100-4530
5. Mount the transmitter head.
Postrequisites
Connect the wiring.
3.5.3
Threaded tank connection
Prerequisites
Note
PTFE covered probes must be handled carefully to prevent damage to the coating.
Procedure
1. For adapters with BSPP (G) threads, place a suitable gasket on top of the tank
2. For adapters with NPT threads, use anti-seize paste or PTFE tape according to your
Reference Manual
Torque 30 ft-lb (40 Nm)
60 mm
flange.
site procedures.
Mechanical installation
April 2019
71