Emerson 5301HxxxxxxxxxxxxxxZZ Series Reference Manual page 427

Guided wave radar level transmitter
Table of Contents

Advertisement

Reference Manual
00809-0100-4530
Table F-2: Level Transducer Block Parameters and Descriptions
Parameter
MODE_BLK
BLOCK_ERR
UPDATE_EVT
BLOCK_ALM
TRANSDUCER_DIRECTORY
TRANSDUCER_TYPE
XD_ERROR
COLLECTION_DIRECTORY
RADAR_LEVEL_TYPE
RADAR_LEVEL
RADAR_LEVEL_RANGE
RADAR_ULLAGE
RADAR_LEVELRATE
RADAR_LEVELRATE_RANGE
RADAR_LEVEL_SIGNAL_STRENGTH
RADAR_LEVEL_SIG-
NAL_STRENGTH_RANGE
RADAR_VOLUME
RADAR_VOLUME_RANGE
RADAR_INTERNAL_TEMPERATURE
RADAR_INTERNAL_TEMPERA-
TURE_RANGE
VOLUME_UPPER
Reference Manual
Index Number
Description
5
The actual, target, permitted, and normal modes of the
block. Target: The mode to "go to" Actual: The mode
the "block is currently in" Permitted: Allowed modes
that target may take on Normal: Most common mode
for target
6
This parameter reflects the error status associated with
the hardware or software components associated with
a block. It is a bit string, so that multiple errors may be
shown.
7
This alert is generated by any change to the static data.
8
The block alarm is used for all configuration, hardware,
connection failure or system problems in the block.
The cause of the alert is entered in the subcode field.
The first alert to become active will set the Active
status in the Status parameter. As soon as the
Unreported status is cleared by the alert reporting task,
another block alert may be reported without clearing
the Active status, if the subcode has changed.
9
Directory that specifies the number and starting
indices of the transducers in the transducer block.
10
Identifies the transducer.
11
A transducer block alarm subcode.
12
A directory that specifies the number, starting indices,
and DD Item ID's of the data collections in each
transducer within a transducer block.
13
Not used
14
Level
15
See
16
Distance (Ullage)
17
Level Rate
18
See
19
Signal strength
20
See
21
Volume
22
See
23
Internal Temperature
24
Range, unit and number of decimals
25
The calculated volume value of the upper product at
the current level and interface
Level Transducer Block
(continued)
Table F-10
Table F-11
Table F-13
Table F-14
April 2019