Product Data Sheet
00813-0100-4530, Rev DA
Superior Performance Guided Wave Radar
Level and Interface Transmitter
• Industry leading measurement capability and
reliability provided by direct switch technology
• Increased plant availability with advanced
diagnostics and PlantWeb
• Increased safety and proven FMEDA suitable
for SIL2 with a SFF>90%
• Reduced cost and increased safety from the
robust modular design
• Reduced instrument count and process
penetrations with a MultiVariable™ transmitter
• Improved throughput and product quality due
to superior performance and accuracy
• Reduced startup cost through powerful and
easy-to-use configuration tools and seamless
plant integration
• Improved EMC performance and higher
safety with smart galvanic interface
• Reduced operating costs with predictive
maintenance and easy troubleshooting
Taking Guided Wave Radar Benefits to the Next Level . . . . . . . . . . . . . . . . . . . . . . page 2
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16
Functional Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16
Performance Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 28
Physical Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 31
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 36
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 39
www.rosemount.com
A.P.O. - ELMOS v.o.s., Pražská 90, 509 01 Nová Paka, Tel.: +420 493 504 261, Fax: +420 493 504 257, E-mail: apo@apoelmos.cz, Internet:
®
functionality
Contents
Rosemount 5300 Series
www.apoelmos.cz

Advertisement

Table of Contents
loading

Summary of Contents for Emerson Rosemount 5300 Series

  • Page 1: Table Of Contents

    Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Superior Performance Guided Wave Radar Level and Interface Transmitter • Industry leading measurement capability and reliability provided by direct switch technology • Increased plant availability with advanced ® diagnostics and PlantWeb functionality •...
  • Page 2: Taking Guided Wave Radar Benefits To The Next Level

    Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Taking Guided Wave Radar Benefits to the Next Level MEASUREMENT PRINCIPLE Reference pulse Low power, nano-second microwave pulses are guided down a probe submerged in the process media. When a microwave pulse...
  • Page 3 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Best Performance and Uptime • Unique Direct Switch Technology (DST) and Probe End Projection (PEP) improve measurement capability and reliability With Direct Switch Technology • Ability to use single lead probe for long measuring ranges,...
  • Page 4: Ordering Information

    Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Rosemount 5301 and 5302 Level and/or Interface in Liquids Rosemount 5301 and 5302 Guided Wave Radar Level transmitters provide industry leading measurement capabilities and reliability in liquids. Characteristics include: •...
  • Page 5 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 TABLE 1. 5301 and 5302 Level and/or Interface in Liquids Ordering Information ★ The Standard offering represents the most common options. The starred options ( ★ ) should be selected for best delivery.
  • Page 6 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 TABLE 1. 5301 and 5302 Level and/or Interface in Liquids Ordering Information ★ The Standard offering represents the most common options. The starred options ( ★ ) should be selected for best delivery.
  • Page 7 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 TABLE 1. 5301 and 5302 Level and/or Interface in Liquids Ordering Information ★ The Standard offering represents the most common options. The starred options ( ★ ) should be selected for best delivery.
  • Page 8 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 TABLE 1. 5301 and 5302 Level and/or Interface in Liquids Ordering Information ★ The Standard offering represents the most common options. The starred options ( ★ ) should be selected for best delivery.
  • Page 9 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 TABLE 1. 5301 and 5302 Level and/or Interface in Liquids Ordering Information ★ The Standard offering represents the most common options. The starred options ( ★ ) should be selected for best delivery.
  • Page 10 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 (3) Requires option None for sealing (no O-ring). (4) Welding Procedure Qualification Record Documentation will be supplied. (5) For other materials, consult the factory. (6) Consult the factory for this option.
  • Page 11: Specifications

    Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Rosemount 5303 Level for Solids Rosemount 5303 Guided Wave Radar Level transmitter provides industry leading measurement capabilities and reliability on solids. Characteristics include: • Direct Switch Technology and Probe End Projection to handle low reflective media and long measuring ranges •...
  • Page 12 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 TABLE 2. 5303 Level for Solids Ordering Information ★ The Standard offering represents the most common options. The starred options ( ★ ) should be selected for best delivery.
  • Page 13 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 TABLE 2. 5303 Level for Solids Ordering Information ★ The Standard offering represents the most common options. The starred options ( ★ ) should be selected for best delivery.
  • Page 14 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 TABLE 2. 5303 Level for Solids Ordering Information ★ The Standard offering represents the most common options. The starred options ( ★ ) should be selected for best delivery.
  • Page 15 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 ACCESSORIES TABLE 3. Accessories Ordering Information Process Connection - Size/Type (consult the factory for other process connections) (1) (2) Centering discs Outer Diameter Standard Standard ★ 03300-1655-0001 Kit, 2-in. Centering Disk, SST, Rigid Single 1.8 in.
  • Page 16: Functional Specification

    Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Functional Specification General Field of Application Liquids and semi-liquids level and/or liquid/liquid interfaces or solids level • Model 5301, for liquid level or submerged interface measurements • Model 5302, for liquid level and interface measurements •...
  • Page 17 (16-30 Vdc in IS applications, and 20-42.4 Vdc in Explosion-proof / Flameproof applications). For Flameproof/Explosion-proof installations the Rosemount 5300 Series transmitters have a built-in barrier; no external barrier needed. When a Smart Wireless THUM adapter is fitted, it adds a maximum drop of 2.5 Vdc in the connected loop R = Load Resistance ();...
  • Page 18 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Load Limitations Maximum load resistance is determined by the voltage level of the external power supply, as described by: Non-Hazardous Installations Maximum Load Resistance Operating External Power Region Supply Voltage...
  • Page 19 ™ fieldbus is 9-32 Vdc (9-30 Vdc in IS applications, and 16-32 Vdc OUNDATION in Explosion-proof/Flameproof applications) The input voltage for FISCO, IS applications is 9-17.5 Vdc For Flameproof/Explosion-proof installations the Rosemount 5300 Series transmitters have a built-in barrier; no external barrier needed. Quiescent Current Draw 21 mA...
  • Page 20 (RS-485) HART - POWER Ambients > 60 ºC HART Use wiring rated HART + for min 90 ºC Power Supply 120 120 RS-485 Bus For Flameproof/Explosion-proof installations the Rosemount 5300 Series transmitters have a built-in barrier; no external barrier needed.
  • Page 21 ™ fieldbus (see Product Data Sheet, OUNDATION Document No. 00813-0100-4377) Configuration Tools HART: Rosemount Radar Master, Emerson Field Communicator, AMS Device Manager, or any other DD (Device Description) compatible host system ™ fieldbus: Rosemount Radar Master, Emerson Field Communicator, DeltaV, or any OUNDATION other DD (Device Description) compatible host system DTM (compliant with version 1.2 of the FDT/DTM specification) supporting configuration in for...
  • Page 22 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Temperature and Pressure Limits Ambient Temperature The maximum and minimum ambient temperature for the electronics depends on the process temperature (as described by the graph below) and on the approval (see “Product Certifications” on page 36).
  • Page 23 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Process Temperature Standard (Std) tank connection (Operating Temperature and Pressure code S): Max. Rating, Standard Connections Pressure psig (bar) 580 (40) PTFE covered probe and flange 232 (16) (model code 7) Temperature °F (°C)
  • Page 24 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Cryogenic Temperature tank connection (Operating Temperature and Pressure code C): Max. Rating, C Connections Pressure psig (bar) Temp. °F (°C) -320 (-196) -200 (-129) ASME / ANSI Flange Rating 316L SST flanges according to ASME B16.5 Table 2-2.3:...
  • Page 25 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Interface Measurements Considerations The Rosemount 5302 is a good 5302 5301 choice for measuring the interface of oil and water, or other liquids with significant dielectric differences. It is also...
  • Page 26 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 High Pressure Steam Applications Considerations Saturated steam under high pressure can influence radar level transmitter measurements. Rosemount 5301 with Dynamic Vapor Compensation (DVC) will Minimum distance for dynamic automatically compensate for compensation up to level 100%: 17.3 in.
  • Page 27 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 TABLE 6. Alloy C-276: conditions used for flange strength calculations Bolting material Gasket Flange material Hub material HP/HTHP/C ASME / Soft (1a) with min. Spiral wound gasket with SB462 Gr. N10276 ANSI Thickness 1.6 mm...
  • Page 28: Performance Specification

    Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Performance Specification General Reference Conditions Single standard probe, 77 °F (25 °C) in water and ambient pressure Reference Accuracy ± 0.12 in. (3 mm) or 0.03% of measured distance, whichever is greatest Repeatability ±...
  • Page 29 See Table 8 on page 30 for each probe’s measuring range and minimum dielectric constant. Due to the measuring range depending on the application and factors described below, the values are a guideline for clean liquids. For more information, ask your local Emerson Process Management representative...
  • Page 30 (1) Consult your local Emerson Process Management representative in the case of agitation/turbulence and high viscous products. (2) Be cautious in HTHP viscous or crystallizing media applications where temperature at instrument connection is significantly lower than process temperature with risk of coating in the upper part of probe that may reduce the measurement signal.
  • Page 31: Physical Specification

    Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Physical Specification Housing and Enclosure Type Dual compartment (terminal compartment and the electronics are completely separated). Two entries for conduit or cable connections. The transmitter housing can be rotated in any direction Electrical Connection ½...
  • Page 32 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Material Exposed To Standard Probe (Operating Temperature and Pressure code S): Tank Atmosphere • Material model code 1: 316L SST (EN 1.4404), PTFE, PFA, and O-ring materials • Material model code 2: Alloy C-276 (UNS N10276), PTFE, PFA, and O-ring materials •...
  • Page 33 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Minimum Clearance (See Table 11 on page 35) Nozzle Height Clearance to tank wall Long Stud (9.8 in./250 mm) When using single flexible probes in tall and narrow nozzles, a Long...
  • Page 34 For additional information, see the Rosemount 9901 Chamber for Process Level Instrumentation Product Data Sheet (Document Number 00813-0100-4601) Existing Chamber A Rosemount 5300 Series transmitter is the perfect replacement in an existing displacer chamber. Proprietary flanges are offered, enabling use of existing chambers to make installation easy.
  • Page 35 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Centering Discs To prevent the probe from contacting the chamber or pipe wall, centering discs are available for rigid single, flexible single, and flexible twin lead probes. The disc is attached to the end of the probe. Discs are made of stainless steel, Alloy C-276, Alloy 400, or PTFE.
  • Page 36: Product Certifications

    The most recent revision of the EC declaration of conformity can be found at www.rosemount.com. Safety Instrumented Systems (SIS) The Rosemount 5300 Series has been evaluated by a third party, Exida, against hardware requirements according to IEC 61508. With a FMEDA (Failure Modes, Effects and...
  • Page 37 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Canadian Standards Association (CSA) Approval IECEx Approval This product meets the Dual Seal Requirements of IECEx NEM 06.0001X ANSI/ISA 12.27.01-2003. SPECIAL CONDITIONS FOR SAFE USE (X) Cert. no. 1514653 The intrinsically safe circuits do not withstand the 500 Vac test as specified in IEC 60079-11 clause 6.4.12.
  • Page 38 OUNDATION Refer to Certificates: GYJ081080X for Ex ia ll C T4 and GYJ081130X for Ex iad ll C T4. For detailed information, refer to the Rosemount 5300 Series Reference Manual (Document No. 00809-0100-4530). Flameproof: HART model: Ex iad IIC T4 (-40 °C<T <+70 °C)
  • Page 39: Dimensional Drawings

    Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 Dimensional Drawings Dimensions are in inches (millimeters) RIGID SINGLE LEAD PROBE WITH FLANGE CONNECTION 5.2 (133) 7.1 (180) ½ - 14 NPT 3.4 (87) 3.6 (92) Optional adapters: M20x1.5,...
  • Page 40 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 RIGID SINGLE LEAD PROBE WITH TRI-CLAMP CONNECTION Dimensions are in inches (millimeters) 7.1 (180) 5.2 (133) ½ - 14 NPT 3.4 (87) 3.6 (92) Optional adapters: M20x1.5, eurofast and minifast 7.4 (188.5)
  • Page 41 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 RIGID SINGLE LEAD PROBE WITH THREADED CONNECTION Dimensions are in inches (millimeters) NPT 1/1½/2 inch NPT 1/1½/2 inch 7.1 (180) 5.2 (133) ½ - 14 NPT Optional 3.4 (87) 3.6 (92)
  • Page 42 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 FLEXIBLE SINGLE LEAD PROBE WITH FLANGE CONNECTION Dimensions are in inches (millimeters) 5.2 (133) 7.1 (180) ½ - 14 NPT 3.4 (87) 3.6 (92) Optional adapters: eurofast and minifast 7.4 (188.5)
  • Page 43 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 FLEXIBLE SINGLE LEAD PROBE WITH TRI-CLAMP CONNECTION Dimensions are in inches (millimeters) 5.2 (133) 7.1 (180) 3.4 (87) 3.6 (92) ½ - 14 NPT Optional adapters: eurofast and 7.4 (188.5) minifast 10.1 (257.5)
  • Page 44 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 FLEXIBLE SINGLE LEAD PROBE WITH THREADED CONNECTION Dimensions are in inches (millimeters) NPT 1/1½/2 inch NPT 1/1½/2 inch 5.2 (133) 7.1 (180) ½ - 14 NPT 3.4 (87) 3.6 (92)
  • Page 45 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 COAXIAL PROBE WITH FLANGE CONNECTION Dimensions are in inches (millimeters) 7.1 (180) 5.2 (133) ½ - 14 NPT 3.4 (87) 3.6 (92) Optional adapters: M20x1.5, eurofast and minifast 7.4 (188.5) 10.1 (257.1)
  • Page 46 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 COAXIAL PROBE WITH THREADED CONNECTION Dimensions are in inches (millimeters) NPT 1/1½/2 inch NPT 1/1½/2 inch 5.2 (133) 7.1 (180) ½ - 14 NPT Optional 3.4 (87) 3.6 (92) adapters: M20x1.5,...
  • Page 47 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 RIGID TWIN LEAD PROBE Dimensions are in inches (millimeters) NPT 1½ / 2 inch NPT 1½ / 2 inch G 1½ inch 5.2 (133) 7.1 (180) 7.1 (180) ½ - 14 NPT...
  • Page 48 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 FLEXIBLE TWIN LEAD PROBE Dimensions are in inches (millimeters) NPT 1½ / 2 inch NPT 1½ / 2 inch G 1½ inch 7.1 (180) 7.1 (180) 5.2 (133) ½ - 14 NPT Optional 3.4 (87)
  • Page 49 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 BRACKET MOUNTING Dimensions are in inches (millimeters) Pipe diameter max 2.5 in. (64 mm) 5.2 (133) Pipe mounting Pipe mounting (vertical pipe) (horizontal pipe) 2.2 (57) 0.3 (7) 2.8 (70) 0.8 (20)
  • Page 50 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 REMOTE HOUSING Dimensions are in inches (millimeters) 7 (180) 5.2 (133) (92) (87) 7.4 (188.5) 5.2 (133) 3, 6, 9 ft. (1, 2, or 3 m) 1.4 (35) 6.9 (175) Standard Variant...
  • Page 51 Product Data Sheet 00813-0100-4530, Rev DA Rosemount 5300 Series December 2010 SPECIAL FLANGES AND FLUSHING CONNECTION RINGS Dimensions are in inches (millimeters) Raised Face Recessed Face D: Outside diameter B1: Flange thickness with gasket surface B2: Flange thickness without gasket surface...
  • Page 52 The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. Fisher is a mark owned by Fisher Controls International LLC, a member of the Emerson Process Management business division of Emerson Electric Co.

This manual is also suitable for:

Rosemount 5302Rosemount 5301Rosemount 5303

Table of Contents