Service and troubleshooting
April 2019
7.9.9
Open the configuration report
The configuration report shows what configuration changes have been done to the
transmitter compared to the factory configuration. The report compares a specified
backup file with the default transmitter configuration.
Procedure
1. In Rosemount Radar Master, select Tools → Configuration Report.
2. Browse to desired backup file to generate the configuration report from, and then
7.9.10
Reset to factory settings
Reset to factory settings using Rosemount Radar Master
This function resets all or a specific part of the holding registers to factory settings.
Prerequisites
Note
It is recommended that a backup of the configuration is done before the factory reset.
Then the old transmitter configuration can be loaded if necessary.
Procedure
Select Tools → Factory Settings.
216
select Open.
Information on probe type, software versions, software and hardware
configuration, and unit code is presented.
Figure 7-24: The Configuration Report Window in Rosemount Radar Master
Reference Manual
00809-0100-4530
Rosemount 5300 Level Transmitter