Emerson 5301HxxxxxxxxxxxxxxZZ Series Reference Manual page 142

Guided wave radar level transmitter
Table of Contents

Advertisement

Configuration
April 2019
7. Check configuration of Probe Type. The following Probe Types are available:
8. Check the entered Probe Length. See
9. Select the TRANSDUCER1100 block, and then select the Geometry tab.
10. Enter the Tank Height. See
11. Select the Mounting Type.
12. If using pipe, chamber or nozzle, then select the Inner Diameter.
142
Rigid twin
Flexible twin
Coaxial, coaxial HP/C, coaxial HTHP
Coaxial large, Coaxial large HP/C
Rigid single, rigid single HTHP/HP/C, rigid single PTFE
Flexible single, flexible single HTHP/HP/C, flexible single PTFE
The transmitter automatically makes some initial calibrations based on the selected
Probe Type. Normally, the Probe Type is pre-configured at the factory.
Probe length
for further information.
Tank height
for further information.
Reference Manual
00809-0100-4530
Rosemount 5300 Level Transmitter

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents