Product certifications
April 2019
Special Conditions for Safe Use (X):
1. WARNING – Potential Electrostatic Charging Hazard – The enclosure contains non-
2. WARNING – The apparatus enclosure contains aluminum and is considered to
B.5.2
I5 Intrinsic Safety (IS), Nonincendive (NI)
Certificate FM16US0444X
Standards FM Class 3600 – 2018; FM Class 3610 – 2010; FM Class 3611 – 2004; FM
Markings
Special Conditions for Safe Use (X):
1. WARNING –Potential Electrostatic Charging Hazard – The enclosure contains non-
2. WARNING – The apparatus enclosure contains aluminum and is considered to
Entity parameters HART 30 V
Entity parameters
Fieldbus
B.5.3
IE FISCO
Certificate FM16US0444X
Standards FM Class 3600 – 2018; FM Class 3610 – 2010; FM Class 3611 – 2004; FM
Markings
360
metallic material. To prevent the risk for electrostatic sparking the plastic surface
should only be cleaned with a damp cloth.
constitute a potential risk of ignition by impact or friction. Care must be taken into
account during installation and use to prevent impact or friction.
Class 3615 – 2006; FM Class 3810 – 2005; ANSI/ISA 60079-0 – 2013;
ANSI/ISA 60079-11 – 2012; ANSI/NEMA 250 – 2003;
IS CL I, II, III, DIV 1, GP A, B, C, D, E, F, G in accordance with control drawing
9240030-936; IS (Entity) CL I, Zone 0, AEx ia IIC T4 in accordance with
control drawing 9240030-936, NI CL I, II, III DIV 2, GP A, B, C, D, F, G; T4; -50
°C ≤ Ta ≤ 60 °C / 70 °C; Type 4X
metallic material. To prevent the risk for electrostatic sparking the plastic surface
should only be cleaned with a damp cloth.
constitute a potential risk of ignition by impact or friction. Care must be taken into
account during installation and use to prevent impact or friction.
Ui
30 V
Class 3615 – 2006; FM Class 3810 – 2005; ANSI/ISA 60079-0 – 2013;
ANSI/ISA 60079-11 – 2012; ANSI/NEMA 250 – 2003;
IS CL I, II, III, DIV 1, GP A, B, C, D, E, F, G; T4; in accordance with control
drawing 9240030-936; IS CL I, Zone 0 AEx ia IIC T4 in accordance with
control drawing 9240030-936; -50 °C ≤ Ta ≤ 60 °C / 70 °C; Type 4X
Ii
Pi
130 mA
1 W
300 mA
1.3 W
Rosemount 5300 Level Transmitter
Reference Manual
00809-0100-4530
Ci
Li
7.26 nF
0
0
0