Screen: 6.3.0.0 (type of the volume meter)

>fmax
M type
>M SN
>Size
M Qmin
M Qmax 1000.000 m3
M1m3=
R1m3=
Tot.chan.
VO chan.
VO cycle
<TYPE COMM OUTPUTS>
NOTE! With battery-powered devices, VO cycle has to be at "30 sec".
Screen: 6.4.0.0 (device data)
YOC
>ID
>Ver-EC900-V11.30 DE
SN
Co10:45:53 20.02.2013
Type
Gas1
Gas2
Calc CS
>CS displd
<TYPE COMM OUTPUTS>
NOTE! After you have changed the device type, the device will be rebooted automatically, since
this requires a new system initialization. The parameters of the device will remain unaffected there-
by and will be retained.
..........................................................................................................................................................................................................
Reed 50 Hz
Maximum possible pulse frequency from the volume meter
TRZ
Meter type {TRZ|US|DKZ|VOL|TERZ}
TRZ 348512-01
Serial number of the meter
G-650
Meter size
50.000 m3
Qmin of the meter
Qmax of the meter
1.00000 imp
Meter factor of the measuring channel
1.00000 imp
Meter factor of the reference channel
M
Sel. of the counting channel {Channel M|Channel R|Chan. Vo}
Channel
Aus
Selection of the Vo (original totalizer) input
{Off|Software|Channel M|Channel R|Encoder}
30 sec
Query cycle of the encoder index
{5 sec|10 sec|15 sec|30 sec}
"TYPE" book
2013
Year of construction of the EC 900
00000000000001
Device identification
Software version
210000
Serial number of the EC 900
Commissioning date
EC922
Device type {EC911|EC912|EC921|EC922}
gas
Selection-1 gas type {Off|Natural gas|Hydrogen|Nitrogen|
Natural
Oxygen|Air|Ammonia|Carbon diox.|Helium}
Selection-2 gas type {Off|Neon|Argon|Ethane|Methane|
Off
Ethylene|Propane|n-butane|Krypton|Xenon}
Nein
Selection of the checksum calculation {Yes|No}
C2DA
Program code of checksum
"TYPE" book
OPERATION