CONSTRUCTION AND FUNCTION
..........................................................................................................................................................................................................

Data logger

Maximum values (maximum load)

In order to enable the gas volume corrector to be approved as a maximum-load recording device, it
is necessary to calculate and store the maximum values of a measuring period (hourly values) and
the maximum daily values for the V
12
In detail, the following maximum values are formed:
1. Maximum value of the measuring period within a day
2. Maximum value of the measuring period within a month
3. Maximum daily value within a month
The maximum values of the measuring period for the day are stored in the daily archive. The maxi-
mum values of the measuring period and the maximum daily values for the month are stored in the
monthly archive. For this purpose, the archive groups of the daily and monthly values are extended
by the necessary channels. The current values of the measuring period and the maximum daily val-
ues and the values of the previous period are additionally available as a data element and can be
displayed at any time.
..........................................................................................................................................................................................................
and V
channels.